Total elbow arthroplasty in patients who have elbow fractures caused by gunshot injuries: 8- to 12-year follow-up study
Authors:
- 14 April 2007
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (1) , 17-24
Abstract
Introduction In this retrospective study, we aimed to present 8–12-year clinical and radiographic evaluation of total elbow arthroplasty in young patients who had open fractures due to gunshot injuries. Materials and methods The study included a consecutive series of seven patients who had insertion of total elbow prosthesis (semi-constrained type) for the treatment of comminuted intra-articular elbow fractures resulting from gunshot injuries between 1994 and 1998. All patients were male and the mean age at the time of operation was 23 years. Results The average time from the original fracture to the joint replacement was 26 months (range 14–39). The mean follow-up period was 117 ± 15 months. At the time of the latest follow-up, 5 of 7 elbows had a poor result. Radiological evaluations revealed that three patients had ulnar and two patients had humeral component loosening at the last follow-up examination. No intra-operative complications were observed. In the long-term evaluation, two patients had prosthesis loosening that resulted from deep infection and three patients had aseptic loosening that necessitated re-operation. The prosthesis removal was performed. Conclusion As a result, the patients in whom we implemented total elbow prosthesis in comminuted elbow fractures due to gunshot wounds seemed to get back into active life in the early period without any problem and it seemed that their pain disappeared and their functional capacity increased. In the long period, however, these values showed a distinct decrease with the same patients.Keywords
This publication has 43 references indexed in Scilit:
- Unilateral Hinged External Fixation Frame for Elbow Compression Arthrodesis: The Stepwise Attainment of a Stable 90-Degree Flexion PositionJournal of Orthopaedic Trauma, 2005
- Treatment Results for Open Comminuted Distal Humerus Intra-Articuler Fractures with Ilizarov Circular External FixatorMilitary Medicine, 2003
- Instability after total elbow arthroplastyOrthopedic Clinics of North America, 2001
- Functional outcome comparison of semiconstrained and unconstrained total elbow arthroplastiesJournal of Shoulder and Elbow Surgery, 2000
- Functional Outcome of Semiconstrained Total Elbow Arthroplasty*Journal of Bone and Joint Surgery, 2000
- Total Elbow Replacement in the Treatment of Rheumatoid DiseaseClinical Orthopaedics and Related Research, 1999
- Instability of the Elbow Treated with Semiconstrained Total Elbow Arthroplasty*Journal of Bone and Joint Surgery, 1999
- Total elbow arthroplasty in rheumatoid arthritis: 20 GSBIII prostheses followed 2–5 yearsActa Orthopaedica, 1999
- Stabilizers of capitellocondylar total elbow arthroplastyJournal of Shoulder and Elbow Surgery, 1992
- ARTHROPLASTY OF THE ELBOW. EXPERIENCE WITH THE MARK III GSB PROSTHESISAnz Journal of Surgery, 1986