Ultra-fast steady state free precession and its application to in vivo 1 H morphological and functional lung imaging at 1.5 tesla
Author:
Open Access
- 28 June 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (3) , 657-663
Abstract
Purpose The speed limit for three-dimensional Fourier-encoded steady state free precession (SSFP) imaging is explored on a clinical whole body system and pushed toward a pulse repetition time (TR) close to or even below the 1 ms regime; in the following referred to as ultra-fast SSFP imaging. Methods To this end, contemporary optimization strategies, such as efficient gradient switching patterns, partial echoes, ramp sampling techniques, and a target-related design of excitation pulses were applied to explore the lower boundaries in TR for SSFP-based Cartesian imaging. Results Generally, minimal TR was limited in vivo by peripheral nerve stimulation, allowing a TR ∼1 ms for isotropic resolutions down to about 2 mm. As a result, ultra-fast balanced SSFP provides artifact-free images even for targets with severe susceptibility variations, and native high-resolution structural and functional in vivo 1H imaging of the human lung is demonstrated at 1.5 T. Conclusion On clinical whole body MRI systems, the TR of SSFP-based Cartesian imaging can be pushed toward the 1 ms regime. As a result, ultra-fast SSFP protocols might represent a promising new powerful approach for SSFP-based imaging, not only for lung but also in a variety of clinical and scientific applications. Magn Reson Med 70:657–663, 2013.Keywords
Funding Information
- Siemens Healthcare
This publication has 19 references indexed in Scilit:
- MRI of the lung (1/3): methodsInsights into Imaging, 2012
- Magnetic resonance lung function – a breakthrough for lung imaging and functional assessment? A phantom study and clinical trialRespiratory Research, 2006
- Principles and applications of balanced SSFP techniquesEuropean Radiology, 2003
- Magnetic resonance T2∗ measurements of the normal human lung in vivo with ultra-short echo timesMagnetic Resonance Imaging, 1999
- T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imagingEuropean Journal of Radiology, 1999
- MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequenceEuropean Journal of Radiology, 1999
- Spoiling of transverse magnetization in steady‐state sequencesMagnetic Resonance in Medicine, 1991
- Lung parenchyma: projection reconstruction MR imaging.Radiology, 1991
- Elimination of transverse coherences in FLASH MRIMagnetic Resonance in Medicine, 1988
- Steady-State Free Precession in Nuclear Magnetic ResonancePhysical Review B, 1958