A MEMS Convective Accelerometer Equipped with On-Chip Facilities for Sensitivity Electrical Calibration
Authors:
- Ahmed Amine RekikARAhmed Amine Rekik
- Florence AzaïsFAFlorence Azaïs
- Norbert DumasNDNorbert Dumas
- Frederick MaillyFMFrederick Mailly
- Pascal NouetPNPascal Nouet
- 1 May 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 82-87
Abstract
In this paper, we propose an alternate electrical-only strategy to perform both test and calibration of MEMS convective accelerometers' sensitivity. The idea is calibrate device sensitivity through the adjustment of the power dissipated in the heater element. For this, the system is equipped with an on-chip programmable digital pulse modulated generator and an iterative search procedure based on simple impedance measurements is implemented. The method is evaluated through Monte-Carlo simulations considering typical process variations and results are presented to demonstrate the potentialities of the technique.Keywords
This publication has 2 references indexed in Scilit:
- Modeling and system-level simulation of a CMOS convective accelerometerSolid-State Electronics, 2007
- On-chip analog signal generation for mixed-signal built-in self-testIEEE Journal of Solid-State Circuits, 1999