Design and development of an optical setup to study light attenuation by suspended sediments in water
- 8 May 2026
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (6) , 567
Abstract
Suspended sediment concentration (SSC) and turbidity are two essential measurements used to evaluate water quality, as they reflect their impact on aquatic ecosystems. The conventional method requires manual intervention and is unable to promptly sense any environmental changes due to urban development, surface run-off, erosion, or climatic effects. Herein, an optical sensor is developed using light-dependent resistors (LDRs), which are non-linear devices used to measure light attenuation through turbidity in the liquid medium. It aims to create affordable sensors that can be expanded to monitor SSC levels using specific measurement techniques that require specialized equipment for precise calibration across different turbidity levels. LDRs were tested for resistance response at different path lengths (50–500 cm), SSC levels (0–7500 mg/L), and laser light wavelengths (532 and 650 nm). The study conducted baseline tests in air and water to measure light attenuation by assessing LDR performance at the center, top, and bottom locations. Four calibration models were developed and evaluated for their accuracy based on metrics such as R2, RMSE, NRMSE, MAE, and the agreement index. Of these four models, the BiDoseResp model was found to be the best fitting, with R2 and RMSE values of 0.98 and 150.05 mg/L, respectively. The system measures LDR data through its controlled calibration process. The testing of ionic compounds and matrices through dose–response curves establishes the verification of sensor performance. The study develops real-time SSC monitoring systems that enable sustainable water management and environmental protection in aquatic ecosystems.Keywords
This publication has 38 references indexed in Scilit:
- A human-machine collaborative approach for high-resolution monitoring of suspended sediment dynamics in data-scarce and optically complex watersInternational Journal of Applied Earth Observation and Geoinformation, 2025
- From dishwasher to river: how to adapt a low-cost turbidimeter for water quality monitoringEnvironmental Monitoring and Assessment, 2024
- Integrating deep learning techniques for effective river water quality monitoring and managementJournal of Environmental Management, 2024
- Enhanced river suspended sediment concentration identification via multimodal video image, optical flow, and water temperature data fusionJournal of Environmental Management, 2024
- Comparing in situ turbidity sensor measurements as a proxy for suspended sediments in North-Western European streamsCATENA, 2023
- Scientists’ warning to humanity on the freshwater biodiversity crisisAMBIO, 2020
- Determining suspended solids and total phosphorus from turbidity: comparison of high-frequency sampling with conventional monitoring methodsEnvironmental Monitoring and Assessment, 2019
- Considerations for using turbidity as a surrogate for suspended sediment in small, ungaged streams: Time‐series selection, streamflow estimation, and regional transferabilityRiver Research and Applications, 2018
- Measurement differences between turbidity instruments, and their implications for suspended sediment concentration and load calculations: A sensor inter-comparison studyJournal of Environmental Management, 2017
- A combined use of acoustic and optical devices to investigate suspended sediment in riversAdvances in Water Resources, 2017