Complex Material and Surface Analysis of Anterolateral Distal Tibial Plate of 1.4441 Steel
Open Access
Abstract
Nickel-based austenitic stainless steels are still common for manufacture of implants intended for acute hard tissue reinforcement or stabilization, but the risk of negative reactions due to soluble nickel-rich corrosion products must be considered seriously. Corrosion processes may even be accelerated by the evolution of microstructure caused by excessive heat during machining, etc. Therefore, this study also deals with the investigation of microstructure and microhardness changes near the threaded holes of the anterolateral distal tibial plate containing approx. 14wt.% Ni by composition. There were only insignificant changes of microhardness, grain size, or microstructure orientation found close to the area of machining. In addition, wettability measurements of surface energy demonstrated only minor differences for bulk material and areas close to machining. The cyclic potentiodynamic polarization tests were performed in isotonic physiological solution. The first cycle was used for the determination of corrosion characteristics of the implant after chemical passivation, the second cycle was used to simulate real material behavior under the condition of previous surface damage by excessive pitting corrosion occurring during previous polarization. It was found that the damaged and spontaneously repassived surface showed a three-time higher standard corrosion rate than the “as received” chemically passivated surface. One may conclude that previous surface damage may decrease the lifetime of the implant significantly and increase the amount of nickel-based corrosion products distributed into surrounding tissues.Keywords
Funding Information
- Ministerstvo Školství, Mládeže a Tělovýchovy (CZ.02.1.01/0.0/0.0/17_049/0008441)
- European Regional Development Fund (CZ.02.1.01/0.0/0.0/17_049/0008441)
This publication has 54 references indexed in Scilit:
- Control of the wetting properties of an AISI 316L stainless steel surface by femtosecond laser-induced surface modificationJournal of Micromechanics and Microengineering, 2012
- Corrosion fatigue of biomedical metallic alloys: Mechanisms and mitigationActa Biomaterialia, 2012
- The Impact of Contact Angle on the Biocompatibility of BiomaterialsOptometry and Vision Science, 2010
- Experimental investigation on martensitic transformation and fracture morphologies of austenitic stainless steelInternational Journal of Plasticity, 2009
- Influence of surface wettability on competitive protein adsorption and initial attachment of osteoblastsBiomedical Materials, 2009
- Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environmentActa Biomaterialia, 2008
- Should the galvanic combination of titanium and stainless steel surgical implants be avoided?Injury, 2008
- Comparison of the corrosion resistance of DIN W. Nr. 1.4970 (15%Cr-15%Ni-1.2%Mo-Ti) and ASTM F-138 (17%Cr-13%Ni-2.5%Mo) austenitic stainless steels for biomedical applicationsMaterials Research, 2006
- Metastable pitting corrosion of stainless steel and the transition to stabilityPhilosophical Transactions A, 1992
- Relationship Between Conventional Pitting and Protection Potentials and a New, Unique Pitting PotentialCorrosion, 1992