RESILLIENT LIVING BY OPTIMIZING THE BUILDING FAÇADE IN DESIGNING POST-COVID HOUSING
Open Access
- 26 July 2022
- journal article
- research article
- Published by Malaysian Institute of Planners in PLANNING MALAYSIA
- Vol. 20
Abstract
The living performance in sustainable development outline contributing factors towards efficiency, such as ecological, economic, health, and social integration. The performance of facade design must be emphasised to describe resilient living and access to mitigate the design of post-coronavirus disease (COVID-19) housing. The spread of the pandemic underlines the importance of providing quality of life and wellbeing in the building environment, hence highlighting a crucial need to improve indoor air quality and passive building performance to minimise the transmission of COVID-19 and indoor airborne diseases as a result of poor ventilation. The passive building performance and facade complement the energy demand and reduce heat gain. Currently, passive design and health are emphasised to link the environmental design approach and architecture and highlight the quality-of-life post-pandemic. The study aims to provide important healthy indoor strategies and passive building performance for open-plan home-office design, to investigate the open-plan home design with optimum thermal performance based on the passive indoor environment, and to examine the bioclimatic response and energy efficiency of home-office design during the pandemic. The responsiveness of bioclimatic and modular construction incorporated with the new home-office design aim to save energy through sustainable material. The Integrated Environmental Solutions Virtual Environment (IESVE) computer software was utilised using simulations involving ranges of illuminance levels in daylight and revealed the acceptable levels of between 300 lux to 500 lux for the home office area. The results demonstrated that the optimum range of solar heat gain coefficient (SHGC) of 0.46 and a U-value of 0.04 W/m2 K reduced the indoor temperature by 5 degrees Celsius during peak time and maintained the air-condition at 28 degrees Celsius, which was within thermal comfort level.Keywords
This publication has 20 references indexed in Scilit:
- Impact of the architecture of dye sensitized solar cell-powered electrochromic devices on their photovoltaic performance and the ability to color changeSolar Energy, 2019
- Implementing Green Walls in SchoolsFrontiers in Psychology, 2018
- Daylight and thermal harvesting performance evaluation of a liquid filled prismatic façade using the Radiance five-phase method and EnergyPlusBuilding and Environment, 2017
- The use of vertical greening systems to reduce the energy demand for air conditioning. Field monitoring in Mediterranean climateEnergy and Buildings, 2017
- Green Walls for a Restorative Classroom Environment: A Controlled Evaluation StudyEnvironment and Behavior, 2016
- Developing a green-building design approach by selective use of systems and techniquesArchitectural Engineering and Design Management, 2015
- Evaluation of green walls as a passive acoustic insulation system for buildingsApplied Acoustics, 2015
- Vertical Greenery Systems (VGS) for energy saving in buildings: A reviewRenewable and Sustainable Energy Reviews, 2014
- Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin façade in subtropical Hong KongEnergy and Buildings, 2014
- Concept of Overall Thermal Transfer Value (OTTV) in Design of Building Envelope to Achieve Energy EfficiencyThe International Journal of Thermal and Environmental Engineering, 2010