Whole-Object Fluorescence Lifetime Setup for Efficient Non-Imaging Quantitative Intracellular Fluorophore Measurements
- 20 January 2012
- journal article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 22 (3) , 875-882
Abstract
In the present study we introduce a Whole-Object Fluorescence Life Time (wo-FLT) measurement approach for ease and a relatively inexpensive method of tracing alterations in intracellular fluorophore distribution and in the physical-chemical features of the microenvironments hosting the fluorophore. Two common fluorophores, Rhodamine 123 and Acridine Orange, were used to stain U937 cells which were incubated, with and without either Carbonyl cyanide 3-chlorphenylhydrazon or the apoptosis inducer H2O2. The wo-FLT, which is a non-imaging quantitative measurement, was able to detect several fluorescence decay components and corresponding weights in a single cell resolution. Following cell treatment, both decay time and weight were altered. Results suggest that the prominent factor responsible for these alterations and in some cases to a shift in emission spectrum as well, is the intracellular fluorophore local concentration. In this study it was demonstrated that the proposed wo-FLT method is superior to color fluorescence based imaging in cases where the emission spectrum of a fluorophore remains unchanged during the investigated process. The proposed wo-FLT approach may be of particular importance when direct imaging is impossible.Keywords
This publication has 32 references indexed in Scilit:
- A novel frequency method for quantitative analysis of fluorescence dye concentration by using series photodetector frequency circuit systemSensors and Actuators A: Physical, 2009
- Acridine orange distribution and fluorescence spectra in myoblasts and single muscle fibersCell and Tissue Biology, 2009
- Excitation Energy Migration of Acridine Orange Intercalated into Deoxyribonucleic Acid Thin FilmsThe Journal of Physical Chemistry C, 2007
- Influence of Fluorescence Anisotropy on Fluorescence Intensity and Lifetime Measurement: Theory, Simulations and ExperimentsIEEE Transactions on Biomedical Engineering, 2006
- Tracing apoptosis and stimulation in individual cells by fluorescence intensity and anisotropy decayJournal of Biomedical Optics, 2005
- Analysis of Early Apoptotic Events in Individual Cells by Fluorescence Intensity and Polarization MeasurementsBiochemical and Biophysical Research Communications, 2002
- Monitoring of Dye Adsorption Phenomena at a Silica Glass/Water Interface with Total Internal Reflection Coupled with a Thermal Lens EffectAnalytical Chemistry, 2000
- Caspase-Dependent and -Independent Events in Apoptosis Induced by Hydrogen PeroxideExperimental Cell Research, 2000
- Quantitative binding and aggregation of R123 and R6G rhodamines at the surface of DPPG and DPPS phospholipid vesiclesJournal of Photochemistry and Photobiology A: Chemistry, 1995
- Fluorescence-excitation spectra of acridine orange-DNA and -RNA systemsRadiation and Environmental Biophysics, 1967