Effects of chemical restraint on electroretinograms recorded sequentially in awake, sedated, and anesthetized dogs
Authors:
- Kate S. FreemanKFKate S. Freeman
- Kathryn L. GoodKGKathryn L. Good
- Philip H. KassPKPhilip H. Kass
- Shin Ae ParkSPShin Ae Park
- Natalia NestorowiczNNNatalia Nestorowicz
- Ron OfriRORon Ofri
- 1 July 2013
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 74 (7) , 1036-1042
Abstract
Objective—To quantitatively and qualitatively compare electroretinography (ERG) recordings in awake, sedated, and anesthetized dogs. Animals—Six 6-month-old Beagles. Procedures—A brief ERG protocol for dogs was used. Following 1-minute and subsequent 5-minute dark adaptation, mixed rod-cone responses were recorded bilaterally with a handheld multispecies ERG device with dogs in each of 3 states of consciousness: awake, sedated (dexmedetomidine and butorphanol), and anesthetized (atropine and hydromorphone, followed by propofol and midazolam and anesthetic maintenance with isoflurane). Low- and high-frequency noise levels were quantified via Fourier analysis, and the effect of consciousness state on signal amplitude, implicit time, and noise was analyzed via repeated-measures ANOVA. In addition, 13 veterinary ophthalmologists who were unaware of the dogs’ consciousness states subjectively graded the ERG recording quality, and scores for each tracing were compared. Results—ERG amplitudes were highest in awake dogs and lowest in anesthetized dogs. Implicit times were shortest in awake dogs and longest in anesthetized dogs. Differences in b-wave amplitudes and a-wave implicit times were significant. Neither low- nor high-frequency noise levels differed significantly among consciousness states. Furthermore, no significant differences were identified among observers’ scores assigned to ERG tracings. Conclusions and Clinical Relevance—Anesthesia and sedation resulted in significant attenuation and delay of ERG responses in dogs. Chemical restraint of dogs had no consistently significant effect on low- or high-frequency noise levels or on observer perception of signal quality.Keywords
This publication has 8 references indexed in Scilit:
- Comparison of the effects of three different combinations of general anesthetics on the electroretinogram of dogsDocumenta Ophthalmologica, 2009
- The Effects of Different Anesthetic Agents on Short Electroretinography Protocol in DogsJournal of Veterinary Medical Science, 2009
- The effects of medetomidine hydrochloride on the electroretinogram of normal dogsVeterinary Ophthalmology, 2008
- Propofol modulates inner retina function in BeaglesVeterinary Ophthalmology, 2007
- Dexmedetomidine or medetomidine premedication before propofol–desflurane anaesthesia in dogsJournal of Veterinary Pharmacology and Therapeutics, 2006
- Influence of Recording Electrode Type and Reference Electrode Position on the Canine ElectroretinogramDocumenta Ophthalmologica, 2005
- Guidelines for clinical electroretinography in the dogDocumenta Ophthalmologica, 2002
- Clinical electrophysiology in veterinary ophthalmology – the past, present and futureDocumenta Ophthalmologica, 2002