Exhaled air dispersion and removal is influenced by isolation room size and ventilation settings during oxygen delivery via nasal cannula
- 25 July 2011
- journal article
- Published by Wiley in Respirology
- Vol. 16 (6) , 1005-1013
Abstract
Background and objective: We compared the exhaled air dispersion distances during oxygen delivery via nasal cannula to a human‐patient simulator (HPS) in two different isolation rooms.Methods: Airflow was marked with intrapulmonary smoke for visualization. Oxygen flow was gradually increased from 1 to 5 L/min, with the HPS sitting at 45°. The leakage jet plume was revealed by laser light‐sheet and images captured by high‐definition video. Smoke concentration in the plume was estimated from the light scattered by smoke particles. The experiments were conducted at a double‐door, negative pressure isolation room with a dimension of 4.1 × 5.1 × 2.6 m, pressure of −7.4 Pa and 16 air exchanges/h (ACH) (room A). Results were compared with experiments repeated in a smaller isolation room with a dimension of 2.7 × 4.2 × 2.4 m, pressure of −5 Pa and 12 ACH (room B).Results: Room A: an exhalation jet spread almost horizontally outward from the nostrils of the HPS to 0.66 m and 1 m towards the end of bed when oxygen flow was increased from 1 to 5 L/min respectively. Room B: there was interaction between the downward ceiling ventilation current and the exhaled air from the HPS, leading to deflection of exhaled smoke towards the head of the HPS at an oxygen flow rate of 1 L/min. As oxygen flow was increased gradually to 5 L/min, more room contamination with smoke was noted.Conclusions: Substantial exposure to exhaled air occurs within 1 m towards the end of the bed from patients receiving oxygen via nasal cannula. Room dimension and air exchange rate are important factors in preventing contamination in isolation rooms.Keywords
This publication has 25 references indexed in Scilit:
- Possible Role of Aerosol Transmission in a Hospital Outbreak of InfluenzaClinical Infectious Diseases, 2010
- Airborne transmission of disease in hospitalsJournal of The Royal Society Interface, 2009
- Exhaled Air Dispersion Distances During Noninvasive Ventilation via Different Respironics Face MasksChest, 2009
- Review of clinical symptoms and spectrum in humans with influenza A/H5N1 infectionRespirology, 2008
- How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curveIndoor Air, 2007
- Why Did Outbreaks of Severe Acute Respiratory Syndrome Occur in Some Hospital Wards but Not in Others?Clinical Infectious Diseases, 2007
- An Audible Indication of Exhalation Increases Delivered Tidal Volume During Bag Valve Mask Ventilation of a Patient SimulatorAnesthesia & Analgesia, 2006
- A Model for Educational Simulation of Infant Cardiovascular PhysiologyAnesthesia & Analgesia, 2004
- Performance of an oxygen delivery device for weaning potentially infectious critically ill patients*Anaesthesia, 2004
- Occupational Infectious Diseases or Infectious Occupational Diseases? Bridging the Views on Tuberculosis ControlInfection Control & Hospital Epidemiology, 1993