The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias
Open Access
- 19 April 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (7) , 1015-1021
Abstract
We aimed to evaluate the safety and long-term efficacy of the magnetic navigation system (MNS) in a large number of patients. The MNS has the potential for improving safety and efficacy based on atraumatic catheter design and superior navigation capabilities. In this study, 610 consecutive patients underwent ablation. Patients were divided into two age- and sex-matched groups. Ablations were performed either using MNS (group MNS, 292) or conventional manual ablation [group manual navigation (MAN), 318]. The following parameters were analysed: acute success rate, fluoroscopy time, procedure time, complications [major: pericardial tamponade, permanent atrioventricular (AV) block, major bleeding, and death; minor: minor bleeding and temporary AV block]. Recurrence rate was assessed during follow-up (15 ± 9.5 months). Subgroup analysis was performed for the following groups: atrial fibrillation, isthmus dependent and atypical atrial flutter, atrial tachycardia, AV nodal re-entrant tachycardia, circus movement tachycardia, and ventricular tachycardia (VT). Magnetic navigation system was associated with less major complications (0.34 vs. 3.2%, P = 0.01). The total numbers of complications were lower in group MNS (4.5 vs. 10%, P = 0.005). Magnetic navigation system was equally effective as MAN in acute success rate for overall groups (92 vs. 94%, P = ns). Magnetic navigation system was more successful for VTs (93 vs. 72%, P < 0.05). Less fluoroscopy was used in group MNS (30 ± 20 vs. 35 ± 25 min, P < 0.01). There were no differences in procedure times and recurrence rates for the overall groups (168 ± 67 vs. 159 ± 75 min, P = ns; 14 vs. 11%, P = ns; respectively). Our data suggest that the use of MNS improves safety without compromising efficiency of ablations. Magnetic navigation system is more effective than manual ablation for VTs.Keywords
This publication has 31 references indexed in Scilit:
- Initial Clinical Experience with the New Irrigated Tip Magnetic Catheter for Ablation of Scar‐Related Sustained Ventricular Tachycardia: A Small Case SeriesJournal of Cardiovascular Electrophysiology, 2009
- Impact of Remote Magnetic Catheter Navigation on Ablation Fluoroscopy and Procedure TimePacing and Clinical Electrophysiology, 2008
- Magnetic Navigation in Left-Sided AV Reentrant Tachycardias: Preliminary Results of a Retrograde ApproachJournal of Cardiovascular Electrophysiology, 2007
- Remote Magnetic Navigation to Guide Endocardial and Epicardial Catheter Mapping of Scar-Related Ventricular TachycardiaCirculation, 2007
- American College of Cardiology/American Heart Association 2006 Update of the Clinical Competence Statement on Invasive Electrophysiology Studies, Catheter Ablation, and CardioversionCirculation, 2006
- Robotic Magnetic Navigation for Atrial Fibrillation AblationJACC, 2006
- Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardiaHeart Rhythm, 2006
- Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation SystemCirculation, 2004
- Linear Ablation Lesions for Control of Unmappable Ventricular Tachycardia in Patients With Ischemic and Nonischemic CardiomyopathyCirculation, 2000
- Transvenous AV junctional ablationAmerican Heart Journal, 1983