Physical sensor difference-based method and virtual sensor difference-based method for visual and quantitative estimation of lower limb 3D gait posture using accelerometers and magnetometers
Authors:
- 1 February 2012
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (2) , 203-210
Abstract
An approach using a physical sensor difference-based algorithm and a virtual sensor difference-based algorithm to visually and quantitatively confirm lower limb posture was proposed. Three accelerometers and two MAG3s (inertial sensor module) were used to measure the accelerations and magnetic field data for the calculation of flexion/extension (FE) and abduction/adduction (AA) angles of hip joint and FE, AA and internal/external rotation (IE) angles of knee joint; then, the trajectories of knee and ankle joints were obtained with the joint angles and segment lengths. There was no integration of acceleration or angular velocity for the joint rotations and positions, which is an improvement on the previous method in recent literature. Compared with the camera motion capture system, the correlation coefficients in five trials were above 0.91 and 0.92 for the hip FE and AA, respectively, and higher than 0.94, 0.93 and 0.93 for the knee joint FE, AA and IE, respectively.Keywords
This publication has 24 references indexed in Scilit:
- Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor systemJournal of Biomechanics, 2009
- Inertial sensor-based knee flexion/extension angle estimationJournal of Biomechanics, 2009
- Functional calibration procedure for 3D knee joint angle description using inertial sensorsJournal of Biomechanics, 2009
- Ambulatory measurement of 3D knee joint angleJournal of Biomechanics, 2008
- Estimation and Visualization of Sagittal Kinematics of Lower Limbs Orientation Using Body-Fixed SensorsIEEE Transactions on Biomedical Engineering, 2006
- Six DOF in vivo kinematics of the ankle joint complex: Application of a combined dual‐orthogonal fluoroscopic and magnetic resonance imaging techniqueJournal of Orthopaedic Research, 2006
- A position based kinematic method for the analysis of human gaitJournal of Mechanical Science and Technology, 2005
- A New Approach to Accurate Measurement of Uniaxial Joint Angles Based on a Combination of Accelerometers and GyroscopesIEEE Transactions on Biomedical Engineering, 2005
- Real-time measurement of patellofemoral kinematics in asymptomatic subjectsThe Knee, 2005
- Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?IEEE Transactions on Biomedical Engineering, 2003