Control characteristics of an automatic matching control system for in vivo EPR spectroscopy
Authors:
- 13 June 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (1) , 223-227
Abstract
A method for estimating the characteristics of an automatic matching control (AMC) system for in vivo electron paramagnetic resonance (EPR) spectroscopy is described. AMC is also known as automatic coupling control (ACC) and is used to compensate for perturbation due to movement of the subject animal. The open-loop function of the AMC system is derived and the characteristics (gain, phase margin, steady-state error, system bandwidth, and disturbance rejection) of the system are examined. The proposed method is supported by experimental findings. The frequency response of perturbation due to the movement of an anesthetized rat was measured with a 1.1-GHz continuous-wave EPR spectrometer. Disturbance rejection with the AMC system was also considered for respiratory motion and the heartbeat of the anesthetized rat, and these perturbations were reduced by about 40 dB in the power spectrum of the output of the diode detector in the spectrometer.Keywords
This publication has 14 references indexed in Scilit:
- Electron Spin Relaxation of Triarylmethyl Radicals in Fluid SolutionJournal of Magnetic Resonance, 2001
- Development of a Resonator with Automatic Tuning and Coupling Capability to Minimize Sample Motion Noise for in Vivo EPR SpectroscopyJournal of Magnetic Resonance, 2001
- Automatic Coupling Control of a Loop–Gap Resonator by a Variable Capacitor Attached Coupling Coil for EPR Measurements at 650 MHzJournal of Magnetic Resonance, 2001
- 300 MHz continuous wave electron paramagnetic resonance spectrometer for small animal in vivo imagingReview of Scientific Instruments, 2000
- Electronically Tunable Surface-Coil-Type Resonator for L-Band EPR SpectroscopyJournal of Magnetic Resonance, 2000
- EPR and DNP Properties of Certain Novel Single Electron Contrast Agents Intended for Oximetric ImagingJournal of Magnetic Resonance, 1998
- Design and Optimization of an Automatic Frequency Control System for a Radiofrequency Electron Paramagnetic Resonance SpectrometerJournal of Magnetic Resonance, Series A, 1995
- Development of an Electronically Tunable L-Band Resonator for EPR Spectroscopy and Imaging of Biological SamplesJournal of Magnetic Resonance, Series B, 1995
- Lithium phthalocyanine: a probe for electron paramagnetic resonance oximetry in viable biological systems.Proceedings of the National Academy of Sciences of the United States of America, 1993
- Preparation and study of a lithium phthalocyanine radical: optical and magnetic propertiesChemical Physics Letters, 1987