Application of Cardinal Points Symmetry Landmarks Distribution Model to B-Mode Ultrasound Images of Transverse Cross-section of Thin-walled Phantom Carotid Arteries
Open Access
- 2 December 2019
- journal article
- Published by European Open Science in European Journal of Engineering and Technology Research
- Vol. 4 (12) , 96-101
Abstract
We had earlier developed a technique based on cardinal point symmetry landmark distribution model (CPS-LDM) to completely characterize the Region of Interest (ROI) of the geometric shape of thick-walled simulated B-mode ultrasound images of carotid artery imaged in the transverse plane. In this paper, this developed technique was applied to completely characterize the region of interest of the geometric shape of B-mode ultrasound images of thin-walled phantom carotid artery imaged in the transverse plane. The developed model employs a combination of fixed landmarks (FLs) and movable landmarks (MLs) to obtain the total landmarks (TLs) that can sufficiently segment the shape of the ROI of the carotid artery. For the phantom carotid arteries, three FLs are fixed on each of the four ROIs determined by the cardinal points North (N), South (S), East (E) and West (W) drawn on the ROIs of the phantom carotid artery. The MLs are determined by the inter-cardinal directions such as North-East (NE), North-West (NW) and so on. The obtained CPS-LDM equation developed allows graphical visualization the optimum number of points that can sufficiently segment the ROIs. ImageJ2 software was used to generate the Cartesian coordinates for each landmark which were then used to generate the Shape Space Pattern (SSP) of the phantom carotid artery ready for further statistical analysis. The results showed that the CPS-LD model is generic and adaptable to a variety of transverse cross-sectional B-mode ultrasound images of thin-walled phantom carotid arteryKeywords
This publication has 8 references indexed in Scilit:
- ImageJ2: ImageJ for the next generation of scientific image dataBMC Bioinformatics, 2017
- Carotid atherosclerotic plaque characterisation by measurement of ultrasound sound speed in vitro at high frequency, 20MHzUltrasonics, 2014
- Basics of Ultrasound Imaging2010
- Handbook of Medical Image Processing and Analysis2009
- Accuracy and variability assessment of a semiautomatic technique for segmentation of the carotid arteries from three‐dimensional ultrasound imagesMedical Physics, 2000
- Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography-methods and validationIEEE Transactions on Medical Imaging, 1999
- Quantitative analysis of ultrasound B-mode images of carotid atherosclerotic plaque: correlation with visual classification and histological examinationIEEE Transactions on Medical Imaging, 1998
- A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media ThicknessStroke, 1997