Risk Factors for Intraocular Pressure Elevation in Steep Trendelenburg Position During Surgery
- 18 December 2025
- journal article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 35 (3) , 185-189
Abstract
Précis: The STP significantly increases IOP during TLH, with a more pronounced effect observed in patients with a high BMI. Purpose: The present study sought to determine the impact of steep Trendelenburg position (STP) on intraocular pressure (IOP) in patients undergoing total laparoscopic hysterectomy (TLH) and to establish the relationship between age, body mass index (BMI), iridocorneal angle, and surgical duration about position-related intraocular pressure changes. Methods: Preoperative ophthalmologic evaluation was performed 1 day before surgery (T0). IOP was measured using a handheld contact tonometer at T1 (5 min after anesthesia), T2 (5 min after pneumoperitoneum), T3 (5 min in STP), T4 (after pneumoperitoneum release), T5 (at the end of surgery in supine position), and T6 (10 min after returning to supine). Surgery duration and patient demographics were recorded. Results: The IOP values were found to be considerably elevated in comparison to the baseline (T0) at all designated time points (T1–T6). There was a progressive decrease in intra-abdominal pressure after the pneumoperitoneum was released (T4–T6). The findings revealed no statistically significant correlation between age and iridocorneal angle on the one hand and IOP values on the other. At T6, a negative correlation was observed between IOP and surgical duration and a positive correlation with BMI. Conclusions: The STP significantly elevates IOP during TLH, and this effect is more pronounced in patients with higher BMI. Identifying such risk factors may guide anesthetic and surgical strategies to minimize ocular complications in procedures requiring this positionKeywords
This publication has 20 references indexed in Scilit:
- Role of excessive weight in intraocular pressure: a systematic review and meta-analysisBMJ Open Ophthalmology, 2023
- Comparison of Trendelenburg Angles in Vaginal, Laparoscopic, and Robotic Uterovaginal Apical Prolapse RepairsJournal of Minimally Invasive Gynecology, 2021
- Effects of positive end-expiratory pressure on intraocular pressure and optic nerve sheath diameter in robot-assisted laparoscopic radical prostatectomyMedicine, 2019
- Correlation between Intraocular Pressure and Angle Configuration Measured by OCTOphthalmology Glaucoma, 2018
- Effects of 25- and 30-degree Trendelenburg positions on intraocular pressure changes during robot-assisted radical prostatectomyProstate International, 2017
- Does steep Trendelenburg positioning effect the ocular hemodynamics and intraocular pressure in patients undergoing robotic cystectomy and robotic prostatectomy?International Urology and Nephrology, 2016
- Intraocular Pressure During Robotic-assisted Laparoscopic Procedures Utilizing Steep Trendelenburg PositioningJournal of Glaucoma, 2015
- The Effect of the Modified Z Trendelenburg Position on Intraocular Pressure during Robotic Assisted Laparoscopic Radical Prostatectomy: A Randomized, Controlled StudyJournal of Urology, 2015
- The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomyBritish Journal of Ophthalmology, 2013
- Intraocular pressure variation during colorectal laparoscopic surgery: standard pneumoperitoneum leads to reversible elevation in intraocular pressureSurgical Endoscopy, 2013