Fragmented red blood cells automated measurement is a useful parameter to exclude schistocytes on the blood film
Authors:
- 14 June 2012
- journal article
- research article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 34 (6) , 566-576
Abstract
Summary: Introduction: The diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult. Mechanical hemolytic anemia with the detection of shistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of shistocytes is still problematic with wide interobserver variations. Some of the latest generation automated blood cell counters (ABCC) propose an original quantitative approach of fragmented red cells (FRC), aiming to be equivalent to the microscopic count. This parameter has been poorly evaluated.Methods: To assess the predictive value (PV) of this test, we conducted studies comparing automated and microscopic counts of FRC/schistocytes, based on the analysis of thousands samples in four university hospitals and using the 2 ABCC currently available (Siemens ADVIA series, Sysmex XE‐2100).Results: Reference range for FRC was Conclusions: Our study validated the utility of the immediately available FRC parameter on ABCC to exclude schistocytes and the diagnosis of TMA.Keywords
This publication has 16 references indexed in Scilit:
- ICSH recommendations for identification, diagnostic value, and quantitation of schistocytesInternational Journal of Laboratory Hematology, 2011
- The Role of Automated Measurement of RBC Subpopulations in Differential Diagnosis of Microcytic Anemia and β-Thalassemia ScreeningAmerican Journal of Clinical Pathology, 2011
- Evaluation of schistocyte monitoring after haematopoietic stem cell transplantationInternational Journal of Laboratory Hematology, 2011
- How I treat patients with thrombotic thrombocytopenic purpura: 2010Blood, 2010
- Survival and relapse in patients with thrombotic thrombocytopenic purpuraBlood, 2010
- Automated Blood Cell CountsAmerican Journal of Clinical Pathology, 2008
- Laboratory measurement of schistocytesInternational Journal of Laboratory Hematology, 2007
- Performance Evaluation of the ADVIA 2120 Hematology Analyzer: An International Multicenter Clinical TrialLaboratory Hematology, 2005
- Comparative Evaluation of Schistocyte Counting by an Automated Method and by Microscopic DeterminationAmerican Journal of Clinical Pathology, 2004
- Improved Platelet Counting Using Two-Dimensional Laser Light ScatterAmerican Journal of Clinical Pathology, 2000