Abstract
Serial block face imaging is a microscopy technique in which the top of a specimen is cut or ground away and a mosaic of images is collected of the newly revealed cross-section. Images collected from each slice are then digitally stacked to achieve 3D images. The development of fully automated image acquisition devices has made serial block face imaging more attractive by greatly reducing labour requirements. The technique is particularly attractive for studies of biological activity within cancellous bone as it has the capability of achieving direct, automated measures of biological and morphological traits and their associations with one another. When used with fluorescence microscopy, serial block face imaging has the potential to achieve 3D images of tissue as well as fluorescent markers of biological activity. Epifluorescence-based serial block face imaging presents a number of unique challenges for visualizing bone specimens due to noise generated by sub-surface signal and local variations in tissue autofluorescence. Here we present techniques for processing serial block face images of trabecular bone using a combination of non-uniform illumination correction, precise tiling of the mosaic in each cross-section, cross-section alignment for vertical stacking, removal of sub-surface signal and segmentation. The resulting techniques allow examination of bone surface texture that will enable 3D quantitative measures of biological processes in cancellous bone biopsies.Keywords
This publication has 19 references indexed in Scilit:
- A Local Adaptive Threshold Strategy for High Resolution Peripheral Quantitative Computed Tomography of Trabecular BoneAnnals of Biomedical Engineering, 2007
- Automated high‐resolution three‐dimensional fluorescence imaging of large biological specimensJournal of Microscopy, 2007
- Automated microscopy system for mosaic acquisition and processingJournal of Microscopy, 2006
- Stress-concentrating effect of resorption lacunae in trabecular boneJournal of Biomechanics, 2006
- Bone Histomorphometry -- The Renaissance?BoneKEy Reports, 2004
- Iterative thresholding for segmentation of cells from noisy imagesJournal of Microscopy, 2000
- Combined inter-observer and inter-method variation in bone histomorphometryBone, 1992
- Consequences of the remodelling process for vertebral trabecular bone structure: a scanning electron microscopy study (uncoupling of unloaded structures)Bone and Mineral, 1990
- Bone histomorphometry: Standardization of nomenclature, symbols, and units: Report of the asbmr histomorphometry nomenclature committeeJournal of Bone and Mineral Research, 1987
- Unbiased stereological estimation of osteoid and resorption fractional surfaces in trabecular bone using vertical sections: Sampling efficiency and biological variationBone, 1987