Pharmacokinetic actions of exendin‐4 in the rat: Comparison with glucagon‐like peptide‐1
Authors:
- 1 August 2001
- journal article
- research article
- Published by Wiley in Drug Development Research
- Vol. 53 (4) , 260-267
Abstract
Exendin‐4, originally isolated from saliva of the lizard Heloderma suspectum, shares 53% sequence homology and several potentially antidiabetic actions with the mammalian hormone glucagon‐like peptide‐1(7‐36)amide (GLP‐1). It shows a higher potency and longer duration of effect in vivo, which may be partly attributed to pharmacokinetic properties. The present study compares the pharmacokinetics of GLP‐1 and exendin‐4 in rats after intravenous (iv), subcutaneous (sc), or intraperitoneal (ip) administration. Samples were assayed for active GLP‐1 (7‐36) amide using an enzyme‐linked immunosorbent assay that does not detect GLP‐1 (1‐36‐amide), (1‐37), (9‐36‐amide) or (9‐37). In parallel experiments, samples were assayed for exendin‐4 using a two‐site immunoradiometric assay that reacts specifically with full‐length exendin‐4. The estimated half‐life for GLP‐1 and exendin‐4 were 0.8–4.7 min and 18–41 min for iv bolus, and 4.6–7.1 min and 90–216 min for SC administration, respectively. Half‐lives after ip injection were 0.6–13.5 min for GLP‐1 and 125–174 min for exendin‐4. Bioavailability for GLP‐1 and exendin‐4 was 44–71% and 65–75%, respectively, for sc injection. For ip injection, bioavailability for GLP‐1 and exendin‐4 was 36–67% and 74–76%, respectively. Plasma clearance, as determined from iv infusion data, was 35–38 ml/min for GLP‐1 and 4‐8 ml/min for exendin‐4. Both Co/Cmax and AUC values were proportional to dose with each route of administration. Plasma clearance of exendin‐4 was reduced by 4.4‐fold in nephrectomized animals. In conclusion, exendin‐4 exhibited a much longer plasma half‐life than GLP‐1 in rats after iv, sc, or ip injection, which may contribute in some part to reported differences in duration of biological action of the two peptides. Drug Dev. Res. 53:260–267, 2001.Keywords
This publication has 20 references indexed in Scilit:
- Potential Therapeutic Levels of Glucagon-Like Peptide I Achieved in Humans by a Buccal TabletDiabetes Care, 1996
- Glucagon-like peptide-1(7–37) has a larger volume of distribution than glucagon-like peptide-1(7–36)amide in dogs and is degraded more quickly in vitro by dog plasmaEuropean Journal of Drug Metabolism and Pharmacokinetics, 1996
- Preliminary report Dose-responses for the slowing of gastric emptying in a rodent model by glucagon-like peptide (7–36)NH2, amylin, cholecystokinin, and other possible regulators of nutrient uptakeMetabolism, 1996
- Degradation of glucagon-like peptide-1 by human plasma in vitro yields an N-terminally truncated peptide that is a major endogenous metabolite in vivoThe Journal of Clinical Endocrinology & Metabolism, 1995
- Stable expression of the rat GLP-I receptor in CHO cells: Activation and binding characteristics utilizing GLP-I(7–36)-amide, oxyntomodulin, exendin-4, and exendin(9–39)Peptides, 1994
- Exendin-4 and exendin-(9–39)NH2: agonist and antagonist, respectively, at the rat parietal cell receptor for glucagon-like peptide-1-(7–36)NH2European Journal of Pharmacology: Molecular Pharmacology, 1994
- Rat gastric somatostatin and gastrin release: Interactions of exendin-4 and truncated glucagon-like peptide-1 (GLP-1) amideLife Sciences, 1994
- Dipeptidyl‐peptidase IV hydrolyses gastric inhibitory polypeptide, glucagon‐like peptide‐1(7–36)amide, peptide histidine methionine and is responsible for their degradation in human serumEuropean Journal of Biochemistry, 1993
- Truncated GLP-1 (proglucagon 78?107-amide) inhibits gastric and pancreatic functions in manDigestive Diseases and Sciences, 1993
- Uranyl nitrate-induced acute renal failure in the rat: Micropuncture and renal hemodynamic studiesKidney International, 1974