A Dual Five-Level Inverter-Fed Induction Motor Drive With Common-Mode Voltage Elimination and DC-Link Capacitor Voltage Balancing Using Only the Switching-State Redundancy—Part II
Authors:
- P. N. TekwaniPTP. N. Tekwani
- R. S. KanchanRKR. S. Kanchan
- K. GopakumarKGK. Gopakumar
- 8 August 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 54 (5) , 2609-2617
Abstract
The open-loop control scheme presented in part I of this paper for a dual five-level-inverter-fed induction motor (IM) drive with two dc power supplies maintains dc-link capacitorvoltage balancing and common-mode voltage (CMV) elimination throughout the operating range of the drive. The operating limitation of the proposed open-loop control scheme to take corrective action toward the existing unbalance in the dc-link-capacitor voltages is also pointed out in part I of this paper. As a solution to this, a simple closed-loop control scheme, which is based only on the switching-state redundancy, is proposed in this part of the paper. The proposed closed-loop control scheme not only prevents further unbalancing of capacitor voltages but also takes corrective actions to bring back the capacitor voltages in the balanced state. The proposed closed-loop scheme achieves dc-link capacitorvoltage balancing and elimination of CMV together in the complete modulation range, including overmodulation of up to the 24-step operation. The proposed control scheme does not affect the output fundamental voltage generated by the inverter, as it effectively utilizes only the availability of redundant switching states of the inverter, and does not call for additional power circuit hardware. The scheme is presented with the simulation studies and experimentally verified with a 1.5-kW open-end winding IM drive.Keywords
This publication has 20 references indexed in Scilit:
- Modified SVPWM Algorithm for Three Level VSI With Synchronized and Symmetrical WaveformsIEEE Transactions on Industrial Electronics, 2007
- Three-Level Inverter Scheme with Common Mode Voltage Elimination and DC-Link Capacitor Voltage Balancing for an Open End Winding Induction Motor Drive2005
- Multilevel PWM VSIs: Coordinated Control of Regenerative Three-Level Neutral Point Clamped Pulsewidth-Modulated Voltage Source InvertersIEEE Industry Applications Magazine, 2004
- A control method of a three phase five-level PWM converter2002
- Diode-clamped multilevel converters: a practicable way to balance DC-link voltagesIEEE Transactions on Industrial Electronics, 2002
- Analysis of a four-level DC/DC buck converterIEEE Transactions on Industrial Electronics, 2002
- A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM invertersIEEE Transactions on Power Electronics, 2000
- Novel technique for maintaining balancedinternal DC linkvoltages in diode clamped five-level invertersIEE Proceedings - Electric Power Applications, 1999
- Multilevel converters for large electric drivesIEEE Transactions on Industry Applications, 1999
- A novel PWM scheme for a three-level voltage source inverter with GTO thyristorsIEEE Transactions on Industry Applications, 1996