Ultrasound Improves Cricothyrotomy Success in Cadavers with Poorly Defined Neck Anatomy

Authors:

Abstract
This is the first study systematically assessing whether ultrasound guidance can reduce the complications associated with cricothyrotomy performed in human cadaver. The incidence of injuries to the larynx and trachea during ultrasoundguided cricothyrotomy was significantly lower compared with conventional digital palpation technique (25 vs. 74%), whereas the insertion time was significantly longer with ultrasound than with digital palpation (196 vs. 110 s). Results of this study suggest that ultrasound guidance of the cricothyroid membrane and neck landmarks should be performed before airway management, particularly in patients with difficult palpable neck landmarks and difficult airways. Background: Misidentification of the cricothyroid membrane in a “cannot intubate-cannot oxygenate” situation can lead to failures and serious complications. The authors hypothesized that preprocedure ultrasound-guided identification of the cricothyroid membrane would reduce complications associated with cricothyrotomy. Methods: A group of 47 trainees were randomized to digital palpation (n = 23) and ultrasound (n = 24) groups. Cricothyrotomy was performed on human cadavers by using the Portex® device (Smiths Medical, USA). Anatomical landmarks of cadavers were graded as follows: grade 1—easy = visual landmarks; 2—moderate = requires light palpation of landmarks; 3—difficult = requires deep palpation of landmarks; and 4—impossible = landmarks not palpable. Primary outcome was the complication rate as measured by the severity of injuries. Secondary outcomes were correct device placement, failure to cannulate, and insertion time. Results: Ultrasound guidance significantly decreased the incidence of injuries to the larynx and trachea (digital palpation: 17 of 23 = 74% vs. ultrasound: 6 of 24 = 25%; relative risk, 2.88; 95% CI, 1.39 to 5.94; P = 0.001) and increased the probability of correct insertion by 5.6 times (P = 0.043) in cadavers with difficult and impossible landmark palpation (digital palpation 8.3% vs. ultrasound 46.7%). Injuries were found in 100% of the grades 3 to 4 (difficult–impossible landmark palpation) cadavers by digital palpation compared with only 33% by ultrasound (P < 0.001). The mean (SD) insertion time was significantly longer with ultrasound than with digital palpation (196.1 s [60.6 s] vs. 110.5 s [46.9 s]; P < 0.001). Conclusion: Preprocedure ultrasound guidance in cadavers with poorly defined neck anatomy significantly reduces complications and improves correct insertion of the airway device in the cricothyroid membrane.

This publication has 17 references indexed in Scilit: