Abstract
We are investigating thin foil Faraday collectors as a diagnostic for lost fast ions from tokamak fusion plasmas. Prototype devices have been recently installed in the National Spherical Torus Experiment and DIII-D. Initial results from these devices indicate a loss of energetic ions from a variety of plasma conditions. Results from a device installed immediately outside a thin Be window on ALCATOR C-mod, as a test on the response to moderately intense fluxes of soft x rays indicate an upper limit of about at a plasma electron temperature of 1.8 keV. An important property of the diagnostic is the expected ability to operate under fairly high neutron/gamma radiation backgrounds. We have tested this expectation by measuring the current from a thin (2.5 μm) Ni foil placed in the core of a TRIGA fission reactor. At a maximum steady-state power of 950 kW a current of 1.2 nA/cm2 was measured.
Keywords
This publication has 6 references indexed in Scilit:
- Measurements of Escaping Fast Particles Using a Thin-Foil Charge CollectorFusion Technology, 2001
- Fast ion loss diagnostic plans for the National Spherical Torus ExperimentReview of Scientific Instruments, 2001
- Development and operation of a thin foil Faraday collector as a lost ion diagnostic for high yield d-t tokamak fusion plasmasReview of Scientific Instruments, 1999
- Evaluation of an ITER compatible, thin foil Faraday collector as a lost alpha particle diagnostic for high yield D–T fusion plasmasReview of Scientific Instruments, 1997
- Experimental investigation of thescaling law of fast-ion-produced secondary-electron emissionPhysical Review A, 1991
- Secondary Electron Emission from Al, Cu, Ag and Au Metal Targets under Proton BombardmentJapanese Journal of Applied Physics, 1981