Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
- 5 April 2011
- journal article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 34 (2) , 251-260
Abstract
This study examines the dosimetric accuracy of Gafchromic EBT2 model radiochromic film for use in radiotherapy quality assurance. In this study, film was scanned using an Epson Perfection V700 flatbed scanner in transmission mode at 75 DPI with the subsequent analysis performed using the red and blue colour channels and ImageJ software. Results of this study suggest that the conversion of film optical density to measured dose should, at present, utilise red channel data only, without application of a blue channel correction to the data. For the batch of film examined here, film uniformity and reproducibility appear to have improved compared with published results using older batches. The orientation of the film on the scanner and the side of the film facing the light source were found to have substantial effects on results. Based on the results of this study, it is possible to recommend the use of EBT2 film in routine quality assurance testing for radiotherapy, in situations where a dose uncertainty of up to 2.8% is acceptable.Keywords
This publication has 30 references indexed in Scilit:
- Whole-Brain Radiotherapy With Simultaneous Integrated Boost to Multiple Brain Metastases Using Volumetric Modulated Arc TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Fractionated stereotactic radiotherapy: A method to evaluate geometric and dosimetric uncertainties using radiochromic filmsMedical Physics, 2009
- Optimization of the Gafchromic™ EBT protocol for IMRT QAZeitschrift für Medizinische Physik, 2009
- Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT filmJournal of Applied Clinical Medical Physics, 2008
- Accurate dosimetry with GafChromic™ EBT film of a 6MV photon beam in water: What level is achievable?Medical Physics, 2008
- Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurancePhysics in Medicine & Biology, 2007
- Evaluation of GAFCHROMIC® EBT film for CyberKnife® dosimetryMedical Physics, 2007
- Clinical use of EBT model Gafchromic™ film in radiotherapyMedical Physics, 2006
- Characterization and use of EBT radiochromic film for IMRT dose verificationMedical Physics, 2006
- Absorption spectra variations of EBT radiochromic film from radiation exposurePhysics in Medicine & Biology, 2005