Detection of COVID-19 Patients through SARS-CoV-2 Antigen Assay using Chemiluminescence Immunoassay: Comparison to RT-PCR Method
Open Access
- 30 April 2024
- journal article
- research article
- Published by Biomedpress in Biomedical Research and Therapy
- Vol. 11 (4) , 6333-6338
Abstract
Background: Accurate and reliable diagnostic tools are essential in effectively managing infectious diseases during the ongoing global COVID-19 pandemic. For this study, the RT-PCR assay was used as the reference method, and the objective was to determine the concordance rate, sensitivity, and specificity of the SARS-CoV-2 antigen assay (SARS-CoV-2 Ag) using the chemiluminescence immunoassay (CLEIA) technique for identifying COVID-19 patients. Method: A total of 231 nasopharyngeal swab samples were collected from individuals with either COVID-19 (cycle threshold (Ct) values ≤ 40) or non-COVID-19 (Ct values > 40 or undetected) diagnoses. These samples were examined using the SARS-CoV-2 Ag. Results: The overall concordance rate of the SARS-CoV-2 Ag was 84.0% (194/231), with a sensitivity of 81.4% (162/199) and 100% specificity (32/32). When samples were categorized into two Ct value groups, the SARS-CoV-2 Ag demonstrated a sensitivity of 97.6% for samples with a Ct value ≤ 30 and 2.9% for samples with a Ct value > 30. Moreover, the antigen concentration determined by the SARS-CoV-2 Ag showed a strong inverse correlation with the Ct value obtained from the RT-PCR assay (r = -0.93, p < 0.001). Conclusion: The SARS-CoV-2 Ag proves to be a potentially effective tool for diagnosing and monitoring COVID-19 patients, particularly in settings where the RT-PCR assay is not available.Keywords
This publication has 12 references indexed in Scilit:
- Comparing the diagnostic accuracy of rapid antigen detection tests to real time polymerase chain reaction in the diagnosis of SARS-CoV-2 infection: A systematic review and meta-analysisJournal of Clinical Virology, 2021
- A novel strategy for SARS-CoV-2 mass screening with quantitative antigen testing of saliva: a diagnostic accuracy studyThe Lancet Microbe, 2021
- Comparison of Roche and Lumipulse quantitative SARS-CoV-2 antigen test performance using automated systems for the diagnosis of COVID-19International Journal of Infectious Diseases, 2021
- Performance characteristics of the Abbott Alinity m SARS-CoV-2 assayJournal of Clinical Virology, 2021
- Lumipulse G SARS-CoV-2 Ag assay evaluation using clinical samples from different testing groupsClinical Chemistry and Laboratory Medicine (CCLM), 2021
- Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in ThailandVirology Journal, 2020
- Molecular Diagnosis of COVID-19: Challenges and Research NeedsAnalytical Chemistry, 2020
- To Interpret the SARS-CoV-2 Test, Consider the Cycle Threshold ValueClinical Infectious Diseases, 2020
- Clinical Characteristics of Coronavirus Disease 2019 in ChinaNew England Journal of Medicine, 2020
- Diagnosing COVID-19: The Disease and Tools for DetectionACS Nano, 2020