Towards 3D thermal models standardisation for human body in motion
- 30 July 2013
- journal article
- research article
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 10 (2) , 207-221
Abstract
In this paper, a novel multi-resolution real-time 3D thermal imaging system as potential solution for a human body 3D thermal models standardisation is presented. The system consists of a high-resolution offline 3D scanner and a real-time low-resolution 3D scanner, both of them paired together with a thermal imaging camera. The emphasis of this paper is the presentation of the novel concept of the standardisation of human body 3D thermal models, captured by the multi-resolution real-time 3D thermal imaging system. The standardisation procedure utilises skeleton detection, skeleton transformation, mesh optimisation and texture mapping. The presented concept enables novel and practical methods for human body 3D thermal models comparison and analysis.Keywords
This publication has 5 references indexed in Scilit:
- Recent progress in diagnosing the reliability of electrical equipment by using infrared thermographyInfrared Physics & Technology, 2012
- Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal ImagingJournal of Visualized Experiments, 2011
- Design of a 3-D Infrared Imaging System Using Structured LightIEEE Transactions on Instrumentation and Measurement, 2010
- State-of-The-Art and Applications of 3D Imaging Sensors in Industry, Cultural Heritage, Medicine, and Criminal InvestigationSensors, 2009
- A flexible new technique for camera calibrationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2000