Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses
Authors:
Open Access
- 14 May 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 31 (5) , 523-528
Abstract
The aims of this study were to evaluate intra-examiner repeatability and inter-examiner reproducibility of landmarks using two cephalometric analysing techniques, manual and computerized, and to compare these for speed. One hundred lateral cephalometric radiographs were randomly selected and 11 angular and six linear parameters were traced and measured by two examiners using the manual method and Dolphin Image Software 9.0 on each radiograph. A Student's t-test for paired and independent samples was used to compare the mean values of intra- and inter-examiner differences. Intraclass correlation coefficients (ICC) were calculated to determine intra- and inter-examiner correlation (r value). Both operators were generally consistent in the repeated measurements; however, for one examiner, the differences for Na┴A (P < 0.001), Na┴Pog, and U1–NA (P < 0.01) distance measurements were found to be statistically significant. Intra-examiner repeatability of landmarks both with the manual and Dolphin techniques showed high correlation coefficients. While inter-examiner reproducibility of landmarks was unacceptable, measurement errors with the manual technique were generally comparable with the Dolphin technique. The mean tracing times of the two operators for a single tracing was 2 minutes 41 seconds for Dolphin and 6 minutes 51 seconds for manual tracings. Computer-assisted cephalometric analysis does not increase intra- and inter-examiner reliability but can result in time saving.Keywords
This publication has 16 references indexed in Scilit:
- A comparison of scanned lateral cephalograms with corresponding original radiographsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Cephalometric digitization: A determination of the minimum scanner settings necessary for precise landmark identificationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2001
- Accuracy of computerized automatic identification of cephalometric landmarksAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2000
- Reliability of landmark recording on film and digital lateral cephalogramsEuropean Journal of Orthodontics, 1993
- Bilgisayar Metodu ve Geleneksel Metod İle Yapılan Sefalometrik Ölçümlerin Hassasiyet, Tekrarlanabilirlik ve Zaman Açısından DeğerlendirilmesiTurkish Journal of Orthodontics, 1992
- Sources of error in measurements from cephalometric radiographsEuropean Journal of Orthodontics, 1986
- The analysis of errors in orthodontic measurementsAmerican Journal of Orthodontics, 1983
- The Clinical Significance of Tracing Error in CephalometryBritish Journal of Orthodontics, 1974
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971