Efficacy of intraarterial superselective indocyanine green videoangiography in cerebral arteriovenous malformation surgery in a hybrid operating room
Authors:
- 1 May 2021
- journal article
- research article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 134 (5) , 1544-1552
Abstract
OBJECTIVE: Although intravenous indocyanine green (ICG) videoangiography has been reported to be useful when applied to cerebral arteriovenous malformation (AVM) surgery, the ICG that remains after the procedure makes it difficult to understand the anatomy, to evaluate nidus blood flow changes, and to repeat ICG videoangiography within a short time. Intraarterial ICG videoangiography has emerged as a way to overcome these limitations. The current study presents the results of intraarterial ICG videoangiography undertaken in patients with cerebral AVMs. METHODS: Intraarterial ICG videoangiography was performed in 13 patients with cerebral AVMs. Routine intraoperative digital subtraction angiography at the authors’ institution is performed in a hybrid operating room during AVM surgery and includes the added step of injecting ICG to the contrast medium that is administered through a catheter. RESULTS: Predissection studies were able to visualize the feeder in 12 of 13 cases. The nidus was visualized in 12 of 13 cases, while the drainer was visualized in all cases. After total dissection of the nidus, there was no ICG filling in the drainers found in any of the cases. Washout of the ICG took 4.4 ± 1.3 seconds in the feeders, 9.2 ± 3.5 seconds in the drainers, and 20.9 ± 3.4 seconds in all of the vessels. Nidus flow reduction was confirmed during dissection in 9 of 9 cases. Flow reduction was easy to recognize due to each span being very short. Color-encoded visualization and objective data obtained by Flow 800 analysis reinforced these findings. CONCLUSIONS: The results showed that intraarterial ICG videoangiography was more useful than intravenous ICG videoangiography in cerebral AVM surgery. This was especially effective in the identification of the feeder, nidus, and drainer and in the assessment of the flow dynamics of the nidus. Use of Flow 800 made it simpler and easier to evaluate these findings.Keywords
This publication has 10 references indexed in Scilit:
- Advantage of Microscope Integrated for Both Indocyanine Green and Fluorescein Videoangiography on Aneurysmal Surgery: Case ReportNeurologia medico-chirurgica, 2014
- Uses and limitations of indocyanine green videoangiography for flow analysis in arteriovenous malformation surgeryJournal of Clinical Neuroscience, 2013
- Intra-arterial Indocyanine Green Angiography in the Management of Spinal Arteriovenous FistulaeSpine, 2012
- Enhanced analysis of intracerebral arterioveneous malformations by the intraoperative use of analytical indocyanine green videoangiography: technical noteActa Neurochirurgica, 2011
- Superselective Indocyanine Green Angiography for Selective Revascularization in the Management of Peripheral Cerebral Aneurysms: Fig 1.American Journal of Neuroradiology, 2011
- Intraoperative indocyanine green angiography for obliteration of a spinal dural arteriovenous fistulaJournal of Neurosurgery: Spine, 2009
- Confirmation of blood flow in perforating arteries using fluorescein cerebral angiography during aneurysm surgeryJournal of Neurosurgery, 2007
- Prospective evaluation of surgical microscope—integrated intraoperative near-infrared indocyanine green videoangiography during aneurysm surgeryJournal of Neurosurgery, 2005
- Intraoperative control of extracranial—intracranial bypass patency by near-infrared indocyanine green videoangiographyJournal of Neurosurgery, 2005
- Adverse Reactions due to Indocyanine GreenOphthalmology, 1994