Abstract
We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globesex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment.Keywords
Funding Information
- Narodowa Agencja Wymiany Akademickiej (NAWA ULAM/2020/1/00176)
- Fundacja na rzecz Nauki Polskiej (MAB/2019/12)
- Ministerio de Ciencia, Innovación y Universidades (IJC2018-037508-I)
- L'Oréal-UNESCO “For Women in Science” Spain
- Ministerio de Ciencia, Innovación y Universidades (CSIC JAE Intro Fellowship)
- Horizon 2020 Framework Programme (H2020-ICT-2017 Ref. 779960)
- Ministerio de Ciencia, Innovación y Universidades (FIS2017-84753-R)
- Horizon 2020 Framework Programme (H-2020-MSCACOFUND-2015 Ref. 713694)
- European Research Council (2018-ADG-SILKEYE-833106)
This publication has 79 references indexed in Scilit:
- A New Tonometer—The Corvis ST Tonometer: Clinical Comparison with Noncontact and Goldmann Applanation TonometersInvestigative Ophthalmology & Visual Science, 2013
- Biomechanics of the Human Posterior Sclera: Age- and Glaucoma-Related Changes Measured Using Inflation TestingInvestigative Ophthalmology & Visual Science, 2012
- Corneal and Crystalline Lens Dimensions Before and After Myopia OnsetOptometry and Vision Science, 2012
- Mechanical Characterization of Porcine CorneasJournal of Biomechanical Engineering, 2012
- Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneasBiomedical Optics Express, 2012
- Brillouin Optical Microscopy for Corneal BiomechanicsInvestigative Ophthalmology & Visual Science, 2012
- Scleral mechanics: Comparing whole globe inflation and uniaxial testingExperimental Eye Research, 2011
- Comparative study of corneal strip extensometry and inflation testsJournal of The Royal Society Interface, 2005
- Collagen Gene Expression and the Altered Accumulation of Scleral Collagen during the Development of High MyopiaJournal of Biological Chemistry, 2003
- Über mechanisch-funktionelle Strukturen des AugesGraefe's Archive for Clinical and Experimental Ophthalmology, 1938