Measurement of Red Cell Volume and Splenic Red Cell Pool using 113mIndium
Authors:
- 1 December 1981
- journal article
- research article
- Published by Wiley in British Journal of Haematology
- Vol. 49 (4) , 587-591
Abstract
Summary. Using the lipophilic chelating agent, acetylacetone, red cells have been radiolabelled with the short‐lived, generator‐produced isotope, 113mIn. Following re‐injection of these labelled cells, red cell volume has been measured and compared with corresponding values using 99mTc labelled red cells in 18 patients, and with 51Cr labelled red cells in five patients. 99mTc slightly overestimated red cell volume in relation to 113mIn, but 51Cr values were identical to 113mIn values. There was a close correlation between splenic red cell pool measured with 99mTc and with 113mIn. It was concluded that the intracellular stability and gamma emission of 113mIn make this isotope a superior alternative to 99mTc and 51Cr in measurements of red cell volume and splenic red cell pool.Keywords
This publication has 5 references indexed in Scilit:
- Simplified cell labelling with indium–111 acetylacetoneBritish Journal of Radiology, 1979
- A Simple and Efficient Method of Labelling Red Cells with 99mTc for Determination of Red Cell VolumeBritish Journal of Haematology, 1978
- Quantitative Radioisotope Scanning and its Use in HaematologyClinics in Haematology, 1977
- The elution of 99 Tc m from red cells and its effect on red-cell volume measurementJournal of Clinical Pathology, 1974
- Red-Cell Pooling in Enlarged SpleensBritish Journal of Haematology, 1964