A comparison of coil combination strategies in 3D multi‐channel MRSI reconstruction for patients with brain tumors
- 31 August 2018
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (11) , e3929
Abstract
The goal of this study was to find the most robust algorithm for a phase‐sensitive coil combination of 3D single‐cycle and lactate‐edited, multi‐channel H‐1 point‐resolved spectroscopy (PRESS) localized echo planar spectroscopic imaging (EPSI) data for clinical applications in the brain.Data were acquired over 5–10 minutes at 3T using 8‐ or 32‐channel array coils. Peak referencing with residual water and N‐acetyl‐aspartate, first‐point phasing, generalized least squared (GLS) and whitened singular‐value decomposition (WSVD) combination algorithms were evaluated relative to unsuppressed water with data from a phantom, six volunteers and 55 patients with brain tumors. Comparison metrics were signal‐to‐noise ratio, coefficient of variance and percent signal increase.Where residual water was present, using it as a reference peak for phasing and weighting factors from an imaging calibration scan gave the best overall performance. Greater improvement was seen for large selected volumes (>720 cm3) and for the 32‐channel array (25%) compared with the 8‐channel array (19%). Applying voxel‐by‐voxel phase corrections produced a larger increase in performance for the 32‐ versus 8‐channel coil.We conclude that, for clinically relevant 3D H‐1 PRESS localized EPSI studies, the most robust technique employed individual phase maps generated from high residual water and individual amplitude maps generated from calibration scans.Keywords
Funding Information
- National Institutes of Health (R01 CA127612, P01 CA118816)
This publication has 49 references indexed in Scilit:
- Improved spatial coverage for brain 3D PRESS MRSI by automatic placement of outer-volume suppression saturation bandsJournal of Magnetic Resonance Imaging, 2011
- Implementation of 3 T Lactate-Edited 3D 1H MR Spectroscopic Imaging with Flyback Echo-Planar Readout for Gliomas PatientsAnnals of Biomedical Engineering, 2010
- 1H spectroscopic imaging of human brain at 3 Tesla: Comparison of fast three-dimensional magnetic resonance spectroscopic imaging techniquesJournal of Magnetic Resonance Imaging, 2009
- 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluationMagnetic Resonance in Medicine, 2009
- Short echo spectroscopic imaging of the human brain at 7T using transceiver arraysMagnetic Resonance in Medicine, 2009
- Mapping of brain metabolite distributions by volumetric proton MR spectroscopic imaging (MRSI)Magnetic Resonance in Medicine, 2008
- Comparison of T1 and T2 metabolite relaxation times in glioma and normal brain at 3TJournal of Magnetic Resonance Imaging, 2008
- Proton Magnetic Resonance Spectroscopic Imaging in Newly Diagnosed Glioblastoma: Predictive Value for the Site of Postradiotherapy Relapse in a Prospective Longitudinal StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- The rapid and automatic combination of proton MRSI data using multi-channel coils without water suppressionMagnetic Resonance Imaging, 2007
- Patterns of Recurrence Analysis in Newly Diagnosed Glioblastoma Multiforme After Three-Dimensional Conformal Radiation Therapy With Respect to Pre–Radiation Therapy Magnetic Resonance Spectroscopic FindingsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007