Combined biomechanical and tomographic keratoconus staging: Adding a biomechanical parameter to the ABCD keratoconus staging system
Open Access
- 16 October 2021
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 100 (5) , E1135-E1142
Abstract
Purpose: This retrospective cross‐sectional study evaluated the potential of an additional biomechanical parameter ‘E’ as an addition to the tomographic ABCD ectasia/keratoconus (KC) staging.Methods: The Corvis Biomechanical Factor (CBiF) represents the modified linear term of the Corvis Biomechanical Index (CBI) developed based on 448 KC corneas from the Homburg Keratoconus Center (HKC). The CBiF range was divided into five stages (E0 to E4) to create a grading system according to the ABCD stages. Stage E0 was characterized by values smaller than the 2.5 percentile. The thresholds were created by dividing the CBiF range between the 2.5 and 97.5 percentiles into four groups of equal values (E1–E4). The frequency distribution of ‘E’ was analysed and independently validated based on another 860 KC corneas dataset from Milano and Rio de Janeiro (MR). The relationship between ‘E’ and the ABCD staging was analysed by cross‐tabulation. The specificity of ‘E’ was assessed based on healthy controls (112|851) from both datasets (HKC|MR).Results: ‘E’ was normally distributed with E0 = 37|30, E1 = 86|200, E2 = 155|354, E3 = 101|206, E4 = 69|70 in the KC group and 96.4%|90.5% of the controls classified E0 in the HKC|MR dataset, respectively. Cross‐tabulation revealed that ‘E’ was most comparable to posterior corneal curvature (‘B’) in both datasets, while showing a trend towards more advanced stages in comparison to anterior corneal curvature (‘A’) and thinnest corneal thickness (‘C’).Conclusion: The novel Corvis‐derived parameter ‘E’ provides a biomechanical staging for ectasia/KC potentially enhancing the ABCD staging and may detect abnormalities before tomographic changes, which requires further studies.Keywords
This publication has 28 references indexed in Scilit:
- Detection of Keratoconus With a New Biomechanical IndexJournal of Refractive Surgery, 2016
- Characterization of Ocular Biomechanics in Pellucid Marginal DegenerationCornea, 2016
- Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomographyJournal of Cataract & Refractive Surgery, 2016
- Keratoconus: The ABCD Grading SystemKlinische Monatsblätter für Augenheilkunde, 2016
- Detection of Keratoconus in Clinically and Algorithmically Topographically Normal Fellow Eyes Using Epithelial Thickness AnalysisJournal of Refractive Surgery, 2015
- Understanding the Correlation between Tomographic and Biomechanical Severity of Keratoconic CorneasBioMed Research International, 2015
- Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconusJournal of Cataract & Refractive Surgery, 2015
- Global Consensus on Keratoconus and Ectatic DiseasesCornea, 2015
- Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based TonometerInvestigative Ophthalmology & Visual Science, 2014
- Biomechanics of corneal ectasia and biomechanical treatmentsJournal of Cataract & Refractive Surgery, 2014