Abstract
The mechanical stability of alternate forms of internal fixation of the transforaminal sacral fracture were compared. A transforaminal sacral fracture was made in each of 6 fresh-frozen cadaveric pelvic specimens. Implants compared for fixation included: a single and 2 fully threaded iliosacral screws inserted through the posterior ilium and anchored into the first sacral vertebral body both with and without the addition of a posterior tension band plate; and 2 transiliac bars inserted through the posterior tubercles. The femora of each specimen were potted and fixed to the table of a materials tester. The pelvis was restrained only from flexing and extending, and a compressive load was applied through the lumbar spine, representing a standing loading condition. Flexion of the sacrum and displacement at the fracture site were measured during loading. Although creation of the injury increased motion considerably, there was no measurable increase in stability provided by any of the implants or combination of implants in this model when an anatomic reduction was obtained.Keywords
This publication has 38 references indexed in Scilit:
- Box Plate Fixation of the Symphysis Pubis: Biomechanical Evaluation of a New TechniqueJournal of Orthopaedic Trauma, 1994
- Biomechanical Testing of New and Old Fixation Devices for Vertical Shear Fractures of the PelvisJournal of Orthopaedic Trauma, 1991
- Anterior and posterior internal fixation of vertical shear fractures of the pelvisJournal of Orthopaedic Research, 1991
- Normal pelvic strain pattern in vitroJournal of Biomedical Engineering, 1989
- Motions and loads within the human pelvis: A biomechanical model studyJournal of Orthopaedic Research, 1988
- Two-hole Plate Fixation for Traumatic Symphysis Pubis Diastasis1988
- Posterior Stabilization of Pelvic Fractures by Use of Threaded Compression RodsClinical Orthopaedics and Related Research, 1985
- Mobility of the pubic symphysis: Measurements by an electromechanical methodActa Orthopaedica, 1984
- Analysis and measurement of lumbar trunk loads in tasks involving bends and twistsJournal of Biomechanics, 1982
- THE ARTICULAR SURFACES OF THE SACRO-ILIAC JOINT AND THEIR RELATION TO THE MOVEMENTS OF THE SACRUMCells Tissues Organs, 1954