Deep Learning-Based Dose Prediction for Low-Energy Electron Superficial Radiotherapy
Preprint
- 24 September 2024
- preprint
- Published by Springer Nature in Research Square
Abstract
Background: Accurate and rapid surface dose calculation is critical in superficiallow-energy electron radiotherapy due to the shallow treatment depth and the riskof radiation-induced skin toxicity. Traditional Monte Carlo (MC) simulations,while precise, can be computationally expensive and time-consuming. Methods: To improve both the accuracy and speed of dose calculations, thisstudy combined MC simulations with deep learning techniques. Low-energy electron beams were simulated for six body sites using DOSXYZnrc, producing CTphantoms and corresponding dose distributions. A cascaded 3D-UNet (C3D) model was trained on these MC simulation datasets to predict dose distributionsrapidly. Results: The C3D model demonstrated a mean absolute percentage error(MAPE) of less than 8% for one-dimensional dose curves, with no significantdifferences found in t-tests. The maximum dose difference observed across different body sites in 2D slices was 0.0421 ± 0.0340. The model achieved an overallGamma pass rate of over 92.09 ± 0.51% within 1%/1mm tolerance, and fordose distribution (DD) analysis under the 1% tolerance, the pass rate was 93.58± 0.21%. Additionally, the C3D model completed dose predictions in just 0.42seconds, making it approximately 140,000 times faster than MC simulations. Conclusion: The integration of deep learning with MC simulations significantlyenhances the efficiency of surface dose calculations in superficial electron radiotherapy. The C3D model provides rapid and accurate dose predictions, facilitatingmore efficient treatment planning while maintaining high accuracy compared totraditional MC methods.Keywords
All Related Versions
This publication has 30 references indexed in Scilit:
- GPU-based cross-platform Monte Carlo proton dose calculation engine in the framework of TaichiNuclear Science and Techniques, 2023
- Multi-task deep learning for medical image computing and analysis: A reviewComputers in Biology and Medicine, 2022
- Towards clinical translation of FLASH radiotherapyNature Reviews Clinical Oncology, 2022
- Multi-constraint generative adversarial network for dose prediction in radiotherapyMedical Image Analysis, 2022
- OpenKBP: The open‐access knowledge‐based planning grand challenge and datasetMedical Physics, 2021
- Technical Note: A cascade 3D U‐Net for dose prediction in radiotherapyMedical Physics, 2021
- CT‐less electron radiotherapy simulation and planning with a consumer 3D cameraJournal of Applied Clinical Medical Physics, 2021
- Proton linac-based therapy facility for ultra-high dose rate (FLASH) treatmentNuclear Science and Techniques, 2021
- Clinical translation of FLASH radiotherapy: Why and how?Radiotherapy and Oncology, 2019
- Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam dataPhysics in Medicine & Biology, 1996