Direct comparisons of European primary and secondary frequency standards via satellite techniques
Open Access
- 21 July 2020
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 57 (4) , 045005
Abstract
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of 1.8 × 10 −16 to 3.5 × 10 −16 for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of 6.9 × 10 −16 , and combined overall uncertainties in the range of 4.8 × 10 −16 to 7.7 × 10 −16 .Keywords
All Related Versions
Funding Information
- European Association of National Metrology Institutes (SIB55 ITOC)
This publication has 52 references indexed in Scilit:
- Quantum-Logic Clock with a Systematic Uncertainty belowPhysical Review Letters, 2019
- Atomic clock performance enabling geodesy below the centimetre levelNature, 2018
- Advances in the accuracy, stability, and reliability of the PTB primary fountain clocksMetrologia, 2018
- Is the time right for a redefinition of the second by optical atomic clocks?Journal of Physics: Conference Series, 2016
- Single-Ion Atomic Clock withSystematic UncertaintyPhysical Review Letters, 2016
- Towards a redefinition of the second based on optical atomic clocksComptes Rendus. Physique, 2015
- Systematic evaluation of an atomic clock at 2 × 10−18 total uncertaintyNature Communications, 2015
- Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountainMetrologia, 2014
- Progress in atomic fountains at LNE-SYRTEIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Atomic fountain clocksMetrologia, 2005