TYPICAL VALUES OF DOSIMETRIC DATA FOR CARDIAC FLUOROSCOPY-GUIDED PROCEDURES IN A SOUTH AFRICAN TEACHING HOSPITAL
Authors:
- 30 September 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 196 (3-4) , 153-158
Abstract
Currently there are limited diagnostic reference level (DRL) data for South African (SA) public sector cardiac fluoroscopy-guided procedures (FGPs). A 4-y retrospective study of dosimetric data on 6265 patients determined typical values (50th percentile) of dosimetric data for the seven most frequent cardiac FGPs at a SA teaching hospital. Kerma-area-product (KAP), reference point air Kerma (Ka,r) and fluoroscopy time (FT) were, respectively, calculated for coronary angiography (CA) (n = 1935; 61Gy.cm2, 624 mGy, 5 min); CA with left ventriculography (n = 1687; 85Gy.cm2, 840 mGy, 3.9 min), valve screening (n = 129; 6Gy.cm2, 164 mGy, 2.3 min), percutaneous coronary intervention (n = 1922; 145Gy.cm2, 1569 mGy, 11.9 min), pacemaker implantation (n = 432; 9Gy.cm2, 100 mGy, 6.5 min), pericardial tap (n = 115; 1.9Gy.cm2, 18 mGy, 1.5 min) and transcatheter aortic valve implantation (n = 45; 65Gy.cm2, 658 mGy, 14.1 min). This work presents the largest SA public sector cardiac FGP dosimetric data to date and provides a key resource for future work in this domain.Keywords
This publication has 14 references indexed in Scilit:
- Measurement of patient skin dose and establishment of local diagnostic reference levels for interventional cardiology proceduresRadiation Protection and Environment, 2019
- Establishing the European diagnostic reference levels for interventional cardiologyPhysica Medica, 2018
- Bi-plane and single plane angiography: a study to compare contrast usage and radiation doses for adult cardiac patients in diagnostic studiesBritish Journal of Radiology, 2018
- ICRP Publication 135: Diagnostic Reference Levels in Medical ImagingAnnals of the ICRP, 2017
- P1. A survey of initial patient diagnostic reference levels from selected fluoroscopically guided interventional procedures at Groote Schuur hospitalPhysica Medica, 2016
- Diagnostic reference levels for the vascular, screening and adult cardiology units at Universitas Academic HospitalPhysica Medica, 2015
- Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi‐centre diagnostic reference level in Queensland public hospitalsJournal of Medical Radiation Sciences, 2014
- Establishing diagnostic reference levels for interventional procedures in KenyaRadiography, 2014
- Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levelsMedical Physics, 2012
- Reference levels at European level for cardiac interventional proceduresRadiation Protection Dosimetry, 2008