Abstract
The kinetics of evaporation and condensation on ice condensed from the vapor phase at 190 K has been studied in the range 173–223 K using a suitably calibrated quartz crystal microbalance that was put inside a vacuum chamber that could be used either as a molecular or a stirred flow reactor, depending on the measured pumping speed. The Arrhenius representation of the zero order evaporative flux Jev (molecule cm−2 s−1) displays a discontinuity at 193 ± 2 K that could be observed owing to the degree of precision of the present measurements. For 223 > T > 193 K, Jev = (1.6 ± 0.7) × 1028exp((−10.2 ± 0.5)/RT) molecule cm−2 s−1and for 173 < T < 193 K, Jev = (2.2 ± 0.9) × 1030exp((−12.0 ± 0.5)/RT) molecule cm−2 s−1 where R = 1.987 × 10−3 kcal mol−1 K−1. The corresponding measured rate constant kcond for H2O condensation on ice satisfies the known vapor pressure Peq (H2O) together with Jev thereby affording thermochemical closure of the kinetics which results in the heat of sublimation ΔHsubl 0 = 11.7 ± 0.6 and 12.3 ± 0.5 kcal mol−1 from the above high and low T-range, respectively. Jev is significantly lower than the maximum theoretically allowed value throughout the T-range in agreement with an uptake coefficient for H2O on ice that is significantly smaller than unity. In addition, the negative temperature dependence of kcond or γ reveals a precursor-mediated adsorption/desorption process for the H2O/ice system. The increased evaporative lifetime of pure ice may be important under atmospheric conditions.

This publication has 43 references indexed in Scilit: