Ignition stability was studied in an optical spray guided spark ignition direct injection engine. The impact of intake air dilution with nitrogen, spark plug orientation, ignition system dwell time, and fuel injector targeting was addressed. Crank angle resolved fuel distributions were measured with a high-speed planar laser-induced fluorescence technique for hundreds of consecutive cycles. IMEP, COV of IMEP, burn rates and spark energy delivered to the gas were examined and used in conjunction with the imaging data to identify potential reasons for misfires.