23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
Authors:
- 14 August 2008
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 92 (11) , 1483-1487
Abstract
Aim: To compare the sutureless 23-gauge system with a standard 20-gauge system in pars plana vitrectomy. Methods: 60 patients in two randomised groups were included in this prospective clinical trial. Pars plana vitrectomy with either 23- or 20-gauge instruments was performed. The main outcome measures were postoperative conjunctival injection and pain. Secondary outcome parameters were time of surgery, intraocular pressure, visual acuity and complications. Results: Conjunctival injection (p = 0.0003) and postoperative pain (p = 0.01) were significantly reduced following 23-gauge vitrectomy compared with the 20-gauge procedure. Opening (p = 0.006) and closure times (pConclusion: The 23-gauge system for pars plana vitrectomy offers significantly higher patient comfort during the early postoperative period. Time of surgery is almost equal—a shorter time for wound closure is neutralised by a longer vitrectomy time in the 23-gauge group.Keywords
This publication has 16 references indexed in Scilit:
- Outcomes of 77 Consecutive Cases of 23-Gauge Transconjunctival Vitrectomy Surgery for Posterior Segment DiseaseOphthalmology, 2007
- 25-gauge vs 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trialBritish Journal of Ophthalmology, 2007
- Comparison of Visual Function After Epiretinal Membrane Removal by 20-Gauge and 25-Gauge VitrectomyAmerican Journal of Ophthalmology, 2006
- 25-gauge, sutureless vitrectomy and standard 20-gauge pars plana vitrectomy in idiopathic epiretinal membrane surgery: a comparative pilot studyGraefe's Archive for Clinical and Experimental Ophthalmology, 2006
- Comparison of clear corneal phacoemulsification combined with 25-gauge transconjunctival sutureless vitrectomy and standard 20-gauge vitrectomy for patients with cataract and vitreoretinal diseasesJournal of Cataract & Refractive Surgery, 2005
- Longer-term Outcomes of Transconjunctival Sutureless 25-gauge VitrectomyAmerican Journal of Ophthalmology, 2005
- Outcomes of 140 Consecutive Cases of 25-Gauge Transconjunctival Surgery for Posterior Segment DiseaseOphthalmology, 2005
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1996