An Electrolyte-Gated Graphene Field-Effect Transistor for Detection of Gadolinium(III) in Aqueous Media
Open Access
- 9 March 2023
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 363
Abstract
In this work, an electrolyte-gated graphene field-effect transistor is developed for Gd3+ ion detection in water. The source and drain electrodes of the transistor are fabricated by photolithography on polyimide, while the graphene channel is obtained by inkjet-printing a graphene oxide ink subsequently electro-reduced to give reduced graphene oxide. The Gd3+-selective ligand DOTA is functionalized by an alkyne linker to be grafted by click chemistry on a gold electrode without losing its affinity for Gd3+. The synthesis route is fully described, and the ligand, the linker and the functionalized surface are characterized by electrochemical analysis and spectroscopy. The as functionalized electrode is used as gate in the graphene transistor so to modulate the source-drain current as a function of its potential, which is itself modulated by the concentration of Gd3+captured on the gate surface. The obtained sensor is able to quantify Gd3+ even in a sample containing several other potentially interfering ions such as Ni2+, Ca2+, Na+ and In3+. The quantification range is from 1 pM to 10 mM, with a sensitivity of 20 mV dec−1 expected for a trivalent ion. This paves the way for Gd3+ quantification in hospital or industrial wastewater.Keywords
Funding Information
- University of Rouen Normandy, INSA Rouen Normandy (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- Centre National de la Recherche Scientifique (CNRS) (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- European Regional Development Fund (ERDF) (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- LABEX SynOrg (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- Carnot Institut I2C, the graduate school for research Xl-Chem (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- Région Normandie (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
- Labex SEAM (ANR-11-LABX-0029, ANR-18-EURE-0020 XL CHEM, ANR 11 LABX 086, ANR11 IDEX 05 02)
This publication has 42 references indexed in Scilit:
- Selective ion sensors based on ionophore-modified graphene field-effect transistorsSensors and Actuators B: Chemical, 2013
- Functionalization of Azide-Terminated Silicon Surfaces with Glycans Using Click Chemistry: XPS and FTIR StudyThe Journal of Physical Chemistry C, 2012
- Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing materialMaterials Science and Engineering: C, 2012
- Imaging local electronic corrugations and doped regions in grapheneNature Communications, 2011
- Modular synthesis of poly(perylene bisimides) using click chemistry: a comparative studyPolymer Chemistry, 2011
- XPS analysis of food products: toward chemical functions and molecular compoundsSurface and Interface Analysis, 2008
- Polymer Electrolyte-Gated Organic Field-Effect Transistors: Low-Voltage, High-Current Switches for Organic Electronics and Testbeds for Probing Electrical Transport at High Charge Carrier DensityJournal of the American Chemical Society, 2007
- Viral MRI contrast agents: coordination of Gd by native virions and attachment of Gd complexes by azide–alkyne cycloadditionChemical Communications, 2007
- Novel gadolinium poly(vinyl chloride) membrane sensor based on a new S–N Schiff’s baseAnalytica Chimica Acta, 2003
- Synthesis, Stability, and Structure of Gadolinium(III) and Yttrium(III) Macrocyclic Poly(amino carboxylates)Inorganic Chemistry, 1994