Novel measurement tool and model for aberrant urinary stream in 3D printed urethras derived from human tissue
Open Access
- 11 November 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0241507
Abstract
An estimated 10% of male adults have split or dribbled stream leading to poor hygiene, embarrassment, and inconvenience. There is no current metric that measures male stream deviation. To develop a novel method to measure spray in normal and abnormal anatomical conformations. We developed a novel platform to reliably describe spray. We used cadaveric tissues and 3D Printed models to study the impact of meatal shape on the urinary stream. Cadaveric penile tissue and 3D printed models were affixed to a fluid pump and used to simulate micturition. Dye captured on fabric allowed for spray detection. Spray pattern area, deviation from normal location, and flowrates were recorded. Computational fluid dynamic models were created to study fluid vorticity. Obstructions at the penile tip worsened spray dynamics and reduced flow. Ventral meatotomy improved flowrate (p<0.05) and reduced spray (p<0.05) compared to tips obstructed ventrally, dorsally or in the fossa navicularis. 3D models do not fully reproduce parameters of their parent cadaver material. The average flowrate from 3D model was 10ml/sec less than that of the penis from which it was derived (p = 0.03). Nonetheless, as in cadavers, increasing obstruction in 3D models leads to the same pattern of reduced flowrate and worse spray. Dynamic modeling revealed increasing distal obstruction was correlated to higher relative vorticity observed at the urethral tip. We developed a robust method to measure urine spray in a research setting. Dynamic 3D printed models hold promise as a methodology to study common pathologies in the urethra and corrective surgeries on the urine stream that would not be feasible in patients. These novel methods require further validation, but offer promise as a research and clinical tool.Keywords
Funding Information
- Alafi Foundation (10001)
This publication has 23 references indexed in Scilit:
- Patient-Reported Outcome Measures in Urethral ReconstructionCurrent Urology Reports, 2018
- Does Circumcision Increase Meatal Stenosis Risk?—A Systematic Review and Meta-analysisUrology, 2017
- Evaluation of the Effect of Meatal Stenosis on the Urinary Tract by using Ultrasonography.2017
- Impact Assessment of Urethral Meatus Morphology and Penile Biometry in Transurethral Prostate and Bladder SurgeryAdvances in Urology, 2017
- EAU Guidelines on the Assessment of Non-neurogenic Male Lower Urinary Tract Symptoms including Benign Prostatic ObstructionEuropean Urology, 2015
- The Shape of the Urine Stream — From Biophysics to DiagnosticsPLOS ONE, 2012
- The burden of lower urinary tract symptoms: evaluating the effect of LUTS on health‐related quality of life, anxiety and depression: EpiLUTSBJU International, 2009
- LONG-TERM PATIENT REPORTED OUTCOME AND SATISFACTION AFTER ORAL MUCOSA GRAFT URETHROPLASTY FOR HYPOSPADIASJournal of Urology, 2005
- The Urinary Drop Spectrometer - An Electrooptical Instrument for Urological Analysis Based on the External Urine StreamIEEE Transactions on Biomedical Engineering, 1976
- Measurement of the Elasticity of the Male Urethral Meatus by Urinary Drop SpectrometryUrologia Internationalis, 1976