Interlaboratory Comparison of Three Multiplexed Bead-Based Immunoassays for Measuring Serum Antibodies to Pneumococcal Polysaccharides
Open Access
- 1 May 2010
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 17 (5) , 862-869
Abstract
Serotype-specific IgG, as quantified by a standardized WHO enzyme-linked immunosorbent assay (ELISA), is a serologic end point used to evaluate pneumococcal polysaccharide-based vaccine immunogenicity. Antibodies to each vaccine polysaccharide in licensed multivalent vaccines are quantified separately; this is laborious and consumes serum. We compared three bead-based immunoassays: a commercial assay (xMAP Pneumo14; Luminex) and two in-house assays (of the Health Protection Agency [HPA] and Centers for Disease Control and Prevention [CDC]), using the WHO-recommended standard reference and reference sera ( n = 11) from vaccinated adults. Multiple comparisons of the IgG concentrations for seven conjugate vaccine serotypes were performed by sample (percent error), serotype (equivalency testing), and laboratory (concordance correlation coefficient [CCC]). When comparing concentrations by sample, bead-based immunoassays generally yielded higher antibody concentrations than the ELISA and had higher variability for serotypes 6B, 18C, and 23F. None of the three assays met the current WHO recommendation of 75% of sera falling within 40% of the assigned antibody concentrations for all seven serotypes. When compared by serotype, the CDC and HPA tests were equivalent for five of seven serotypes, whereas the Luminex assay was equivalent for four of seven serotypes. When overall mean IgG concentrations were compared by laboratory, a higher level of agreement (CCC close to 1) was found among bead-based immunoassays than between the assays and WHO assignments. When compared to WHO assignments, the HPA assay outperformed the other assays ( r = 0.920; CCC = 0.894; coefficient of accuracy = 0.972). Additional testing with sera from immunogenicity studies should demonstrate the applicability of this methodology for vaccine evaluation.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of the Specificity of Pneumococcal Polysaccharide Enzyme-Linked Immunosorbent Assay and the Effect of Serum Adsorption Based on Standard Pneumococcal Serogroup- or Serotype-Specific Rabbit AntiseraClinical and Vaccine Immunology, 2009
- Optimization and Validation of a Multiplex, Electrochemiluminescence-Based Detection Assay for the Quantitation of Immunoglobulin G Serotype-Specific Antipneumococcal Antibodies in Human SerumClinical and Vaccine Immunology, 2009
- Suppression of non-specific binding in serological Luminex assaysJournal of Immunological Methods, 2006
- A novel chemistry for conjugating pneumococcal polysaccharides to Luminex microspheresJournal of Immunological Methods, 2006
- Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypesJournal of Immunological Methods, 2005
- Method for Simultaneous Measurement of Antibodies to 23 Pneumococcal Capsular PolysaccharidesClinical and Vaccine Immunology, 2003
- Decline in Invasive Pneumococcal Disease after the Introduction of Protein–Polysaccharide Conjugate VaccineNew England Journal of Medicine, 2003
- A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular PolysaccharidesAmerican Journal of Clinical Pathology, 2002
- Pneumococcal Type 22F Polysaccharide Absorption Improves the Specificity of a Pneumococcal-Polysaccharide Enzyme-Linked Immunosorbent AssayClinical and Diagnostic Laboratory Immunology, 2001
- Determination of the Coefficient of CorrelationScience, 1909