Experimental realization of dynamic fluence field optimization for proton computed tomography
Open Access
- 22 September 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (19) , 195001
Abstract
Proton computed tomography (pCT) has high accuracy and dose efficiency in producing spatial maps of the relative stopping power (RSP) required for treatment planning in proton therapy. With fluence-modulated pCT (FMpCT), prescribed noise distributions can be achieved, which allows to decrease imaging dose by employing object-specific dynamically modulated fluence during the acquisition. For FMpCT acquisitions we divide the image into region-of-interest (ROI) and non-ROI volumes. In proton therapy, the ROI volume would encompass all treatment beams. An optimization algorithm then calculates dynamically modulated fluence that achieves low prescribed noise inside the ROI and high prescribed noise elsewhere. It also produces a planned noise distribution, which is the expected noise map for that fluence, as calculated with a Monte Carlo simulation. The optimized fluence can be achieved by acquiring pCT images with grids of intensity modulated pencil beams. In this work, we interfaced the control system of a clinical proton beam line to deliver the optimized fluence. Using three phantoms we acquired images with uniform fluence, with a constant noise prescription, and with an FMpCT task. Image noise distributions as well as fluence maps were compared to the corresponding planned distributions as well as to the prescription. Furthermore, we propose a correction method that removes image artifacts stemming from the acquisition with pencil beams having a spatially varying energy distribution that is not seen in clinical operation. RSP accuracy of FMpCT scans was compared to uniform scans and was found to be comparable to standard pCT scans. While we identified technical improvements for future experimental acquisitions, in particular related to an unexpected pencil beam size reduction and a misalignment of the fluence pattern, agreement with the planned noise was satisfactory and we conclude that FMpCT optimized for specific image noise prescriptions is experimentally feasible.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (388731804)
- European SocieTy for Radiotherapy and Oncology (Technology Transfer Grant)
- Bavaria-California Technology Center
- Franco-Bavarian University Cooperation Center
This publication has 31 references indexed in Scilit:
- Physics Controversies in Proton TherapySeminars in Radiation Oncology, 2013
- Filtered backprojection proton CT reconstruction along most likely pathsMedical Physics, 2013
- Spot Scanning-Based Proton Therapy for Intracranial Meningioma: Long-Term Results From the Paul Scherrer InstituteInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibrationPhysics in Medicine & Biology, 2012
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- Fluence field optimization for noise and dose objectives in CTMedical Physics, 2011
- A maximum likelihood proton path formalism for application in proton computed tomographyMedical Physics, 2008
- Image covariance and lesion detectability in direct fan-beam x-ray computed tomographyPhysics in Medicine & Biology, 2008
- Reconstruction for proton computed tomography by tracing proton trajectories: A Monte Carlo studyMedical Physics, 2006
- Representation of a Function by Its Line Integrals, with Some Radiological ApplicationsJournal of Applied Physics, 1963