Abstract
To determine the efficacy of the implantable loop recorder (ILR) in patients with congenital heart disease. Retrospective data analyses of all patients with congenital heart disease undergoing ILR implantation in a congenital cardiac centre. Of 78 ILRs implanted between July 2000 and October 2007, 22 (15 male) patients had congenital heart disease. The median age at implantation was 15.5 years (7.0–46.5). Six patients had neurodevelopmental delay. Indications for implantation were syncope ( n = 15), palpitations ( n = 4), and pre-syncope ( n = 3). Median implantation time was 19 months (1–30). Explantation data were available in 16 patients (73%). Implantable loop recorders were explanted following establishment of positive diagnosis ( n = 3), negative diagnosis ( n = 7), and at the end of battery life ( n = 4). One patient died with the ILR in situ . One device eroded after 2 months without further complication. Following ILR interrogation, diagnosed arrhythmias included ventricular tachycardia ( n = 2) and sinus node dysfunction ( n = 1). On the basis of these findings, two patients had intracardiac defibrillators and one patient had a dual-chamber pacemaker implanted. Implantable loop recorders lead to a positive or negative arrhythmic diagnosis following explantation in 71% of patients with congenital heart disease. This is particularly beneficial in patients with neurodevelopmental delay where accurate history is often limited.Keywords
This publication has 18 references indexed in Scilit:
- Digital implantable loop recorders in the investigation of syncope in children: Benefits and limitationsHeart Rhythm, 2006
- Use of the implantable loop recorder in children and adolescentsCardiology in the Young, 2006
- The clinical impact of implantable loop recorders in patients with syncopeEuropean Heart Journal, 2005
- Efficacy of Implantable Loop Recorders in Establishing Symptom-Rhythm Correlation in Young Patients With Syncope and PalpitationsPediatrics, 2003
- Use of an implantable loop recorder in the evaluation of children with congenital heart diseaseAmerican Heart Journal, 2002
- Hemodynamic Benefits of Right Ventricular Outflow Tract Pacing: Comparison with Right Ventricular Apex PacingPacing and Clinical Electrophysiology, 1998
- Factors that influence the development of atrial flutter after the fontan operationThe Journal of Thoracic and Cardiovascular Surgery, 1997
- Benefits and Potential Risks of Atrial Antitachycardia Pacing After Repair of Congenital Heart DiseasePacing and Clinical Electrophysiology, 1995
- Sudden cardiac death and the use of implantable cardioverter-defibrillators in pediatric patients. The Pediatric Electrophysiology Society.Circulation, 1993