Evaluation of strand‐to‐strand capacitance and dissipation factor in thermally aged enamelled coils for low‐voltage electrical machines
Open Access
- 1 October 2019
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (8) , 1170-1177
Abstract
The dissipation factor (i.e. tan δ ) and insulation capacitance (IC) measurements are conventional monitoring methods for assessing the aging level of insulation systems. These quantities provide an invaluable indication of the dielectric losses within the insulating materials. However, how these values are affected by the aging processes due to thermal stresses have until today never been investigated fully. Thus, this study exhibits the influence of thermal aging on tan δ and IC of windings for electrical machines (EMs). The work is performed for class 200, round enamelled magnet wire specimens. The study aims at improving the design process of EMs for short duty cycle applications; hence, its outcome might be included at the design stage for enhancing reliability and lifetime. Random wound coils are chosen in the performed study, because they are the most common winding arrangement for low‐voltage EMs, which are employed in a wide range of applications (e.g. from home appliances to aerospace motors). Based on the collected data, considerations regarding the impact of relative humidity on both the dissipation factor and IC are presented. Finally, the correlation between the partial discharge inception voltage and the diagnostic measurements is experimentally verified.Keywords
Funding Information
- Marie Curie Initial Training Networks (665468)
- University of Nottingham Propulsion Futures Beacon (PF42)
- Ningbo 3315 Innovation Team Scheme (2018A-08-C)
This publication has 26 references indexed in Scilit:
- Effect of repetitive impulsive voltage duty cycle on partial discharge features and insulation endurance of enameled wires for inverter-fed low voltage machinesIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- Evaluation and Current-Response-Based Identification of Insulation Degradation for High Utilized Electrical Machines in Railway ApplicationIEEE Transactions on Industry Applications, 2017
- Qualification of Hairpin Motors Insulation for Automotive ApplicationsIEEE Transactions on Industry Applications, 2016
- Depolarization index for dielectric aging indicator of rotating machinesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Advanced High-Power-Density Interior Permanent Magnet Motor for Traction ApplicationsIEEE Transactions on Industry Applications, 2014
- A novel method to diagnose PWM-fed induction motorsIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Proposition of a New Method for In-Service Monitoring of the Aging of Stator Winding Insulation in AC MotorsIEEE Transactions on Energy Conversion, 2006
- Study of Capacitance and Dissipation Factor Tip-Up to Evaluate the Condition of Insulating Systems for High Voltage Rotating MachinesElectrical Engineering, 2006
- Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windingsIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Dielectric relaxation in solidsJournal of Physics D: Applied Physics, 1999