Theoretical, Experimental, and Optical Coherence Tomography (OCT) Studies of Graft Apposition and Adhesion in Descemets Stripping Automated Endothelial Keratoplasty (DSAEK)
- 1 June 2012
- journal article
- cornea
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (7) , 3839-3846
Abstract
Purpose.: To investigate the effects of adhesion promoting surgical adjuncts in Descemets stripping automated endothelial keratoplasty (DSAEK). The effects of air-fill pressure, duration, use of venting incisions and stromal roughening on fluid dispersion, and donor adhesion strength were examined in theoretical, optical coherence tomography (OCT), and strain gauge models of DSAEK. Methods.: OCT analysis: DSAEK modeled using a microkeratome prepared lenticule inserted under a “recipient” corneo-scleral rim mounted on an artificial anterior chamber. Pressure of 18 mm Hg (n = 6) or 60 mm Hg (n = 6) was applied. The area of interface fluid was measured sequentially. The area of interface fluid before and after opening of venting incisions was measured (n = 6). Adhesion experiments: Direct measurement of adhesion force using a universal testing machine was performed. Peak adhesion after compression at 60 mm Hg/8 minutes, 60 mm Hg/1 minutes, 18 mm Hg/8 minutes, and 18 mm Hg/1 minutes (n = 8 each group) was measured. Subsequently, adhesion after complete removal of interface fluid and after stromal roughening was measured in separate samples (n = 12). Results.: Interface fluid diminishes with time during tamponade at both low and high pressures (P < 0.0001). Pressure had no effect on amount or rate of fluid dispersion. Venting incisions eliminated interface fluid in all samples when opened sufficiently. Adhesion is independent of anterior chamber air tamponade pressure (P = 0.38). Complete removal of interface fluid increases average adhesion (16.0 mN vs. 7.8 mN, P = 0.0001). Roughening of the host stroma increased adhesion (13.8 mN vs. 9.8 mN, P = 0.0034). Conclusions.: Venting incisions and stromal roughening aid adhesion in DSAEK. Sustained high-pressure anterior chamber air tamponade has no demonstrable effect on measured fluid dispersion or adhesion strength.Keywords
This publication has 11 references indexed in Scilit:
- Optical Coherence Tomography, Scheimpflug Imaging, and Slit-Lamp Biomicroscopy in the Early Detection of Graft Detachment After Descemet Membrane Endothelial KeratoplastyCornea, 2011
- Clinical profile of graft detachment and outcomes of rebubbling after Descemet stripping endothelial keratoplastyBritish Journal of Ophthalmology, 2011
- Epithelial Ingrowth After Descemet Stripping Automated Endothelial Keratoplasty: Description of Cases and Assessment With Anterior Segment Optical Coherence TomographyCornea, 2011
- Accuracy of RTVue Optical Coherence Tomography, Pentacam, and Ultrasonic Pachymetry for the Measurement of Central Corneal ThicknessOphthalmology, 2010
- Use of Intraoperative Fourier-Domain Anterior Segment Optical Coherence Tomography During Descemet Stripping Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2010
- Trends in corneal graft surgery in the UKBritish Journal of Ophthalmology, 2010
- Fungal Endophthalmitis After Descemet Stripping Automated Endothelial Keratoplasty-A Case ReportCornea, 2010
- Fixed Dilated Pupil (Urrets-Zavalia Syndrome) and Anterior Subcapsular Cataract Formation After Descemet Stripping Endothelial KeratoplastyCornea, 2009
- Endothelial Keratoplasty: Case Selection in the Learning CurveCornea, 2008
- Histology of Dislocations in Endothelial Keratoplasty (DSEK and DLEK): A Laboratory-Based, Surgical Solution to Dislocation in 100 Consecutive DSEK CasesYearbook of Ophthalmology, 2007