Step Count and Pulse Rate Detection Based on the Contactless Image Measurement Method
- 5 January 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Multimedia
- Vol. 20 (8) , 2223-2231
Abstract
Contactless exercise monitoring is a new trend that makes people feel more comfortable and unconstrained. However, the decrease in accuracy of the pulse rate measurement caused by large motion artifacts is an urgent problem to be solved. In this paper, we proposed a novel approach to monitor step count and improve the accuracy of remote pulse rate measurement based on the image detection method. We designed a chrominance-based adaptive filter and normalization (CADN) method and a domain selection scheme (DSS) to enhance the accuracy of contactless pulse rate measurement during exercise. Various exercises such as biking, stepping, and treadmill running were conducted to evaluate motion robustness of the proposed CADN+DSS and the accuracy of step counts. The results reveal that the detection rates of the proposed step count method are 99.57 % and 99.77% for stepping and treadmill exercise, respectively. The pulse rate accuracy is compared with two state-of-the-arts algorithms- chrominance (CHROM) and chrominance-based adaptive filter (CAD). The results show the proposed CADN+DSS method provides a lower discrepancy between the detected pulse rate and a ground-truth device (Polar H7) for all activities. We expand the scope of contactless measurement for physical activity detection and develop an unfettered step count and pulse rate measurement method in exercise. Therefore, step count and pulse rate can be measured synchronously without relying on any contact sensors.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 105-2221-E-011-150, MOST 106-3011-E-011-001)
This publication has 21 references indexed in Scilit:
- Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of SkinIEEE Transactions on Circuits and Systems for Video Technology, 2014
- Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPGIEEE Transactions on Biomedical Engineering, 2014
- Improved motion robustness of remote-PPG by using the blood volume pulse signaturePhysiological Measurement, 2014
- A Real-Time Pulse Peak Detection Algorithm for the PhotoplethysmogramInternational Journal of Electronics and Electrical Engineering, 2014
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- A Driver’s Physiological Monitoring System Based on a Wearable PPG Sensor and a SmartphoneCommunications in Computer and Information Science, 2011
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Heart rate measurement based on a time-lapse imageMedical Engineering & Physics, 2006
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- Physician advice and support for physical activityAmerican Journal of Preventive Medicine, 2001