Lower district-heating (DH) return temperatures depend on building-side measures whose cost falls on owners while much of their value goes to the network. Existing studies cover what such measures achieve and how motivational tariffs work, but not the owner's choice among them. We ask which measure owners choose, how far it diverges from the network's interest, and whether tariffs and subsidies can redirect it. We model the choice with a multinomial logit over nine measures and doing nothing, coupled to building-stock and building-physics models, for nine Austrian multi-family archetypes in five renovation states, and estimate network value from published cost-reduction gradients (network savings per kelvin). Private choice and network value diverge: the most chosen measure (16.7%) barely lowers the return temperature, whereas the measure with the largest reduction (4.8 K) is chosen least (3.4%). The latter saves the network an estimated EUR 69–384 per building and year but increases the owner's heating cost by EUR 3,100; joint owner–network breakeven would require a gradient eight times the highest published value for heat generation. Danish and Austrian tariffs shift choice shares by at most one percentage point, while a 30% investment subsidy raises the choice shares of the capital-intensive measures that tariffs barely move. After deep renovation, the choice shares of these measures fall below 1%; hence, support should reach owners before or during renovation, as part of its funding. The owner–network value gap is thus a structural barrier: tariffs can steer affordable choices, but high-impact measures need public investment support.