Detections of Arterial Wall in Sonographic Artery Images Using Dual Dynamic Programming
Authors:
- Da-Chuan ChengDa-Chuan Cheng
- Xiaoyi JiangXJXiaoyi Jiang
- 30 May 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Technology in Biomedicine
- Vol. 12 (6) , 792-799
Abstract
We propose a novel dual dynamic programming (DDP) technique for detecting intimal and adventitial layers of the common carotid artery of the B-mode sonographic images. This method embeds the anatomic knowledge into its structure so that the robustness against the speckles is increased. Moreover, it inherits the property of getting the optimal solution as the traditional dynamic programming (TDP). Our experimental study shows that the DDP technique achieves a detection performance comparable to manual tracing achieved by physicians. The results demonstrate that it has the potential to perform qualitatively better than applying TDP twice in intimal and adventitial layer detection on sonographic B-mode images.Keywords
This publication has 27 references indexed in Scilit:
- Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributionsIEEE Transactions on Medical Imaging, 2006
- New non-invasive method for intima-media thickness and intima-media compression measurements2006
- Detection of lumen-intima interface of posterior wall for measurement of elasticity of the human carotid arteryIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- Elasticity Imaging of Atheroma With Transcutaneous UltrasoundCirculation, 2003
- Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic imagesComputer Methods and Programs in Biomedicine, 2002
- Automated detection of local artery wall thickness based on M-line signal processingUltrasound in Medicine & Biology, 1997
- Premature carotid atherosclerosis: does it occur in both familial hypercholesterolemia and homocystinuria? Ultrasound assessment of arterial intima-media thickness and blood flow velocity.Stroke, 1994
- Evidence for in vivo carotid and femoral wall thickening in human hypertension. Groupe de Prévention Cardio-vasculaire en Médecine du Travail.Hypertension, 1993
- Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imagingJournal Of Hypertension, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986