An improved correlation-based anomaly detection approach for condition monitoring data of industrial equipment
Authors:
- 1 June 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 51, 1-5
Abstract
An improved latent correlation anomaly detection (LCAD) method is proposed to detect anomalies from condition monitoring datasets of industrial equipment. Above all, original data were segmented to various work cycles. Then, latent correlation vector (LCV) was used to denote the latent correlation among different parameters. Based on a latent correlation probabilistic model (LCPM), an anomaly detection function (ADF) is formulated to determine the state of equipment. In order to compare this method with previously reported anomaly detection methods, simulated datasets were constructed to evaluate the effectiveness of this method. Another experiment was also conducted to test the applicability of this method based on real flight datasets. Both experiments demonstrated superior accuracy and much lower missing alarm rates of this improved LCAD method.Keywords
This publication has 8 references indexed in Scilit:
- An angle-based subspace anomaly detection approach to high-dimensional data: With an application to industrial fault detectionReliability Engineering & System Safety, 2015
- Detecting continual anomalies in monitoring data stream based on sampling GPR algorithm2015
- Study on Anomaly Detection Algorithm of QAR Data Based on Attribute Support of Rough SetInternational Journal of Hybrid Information Technology, 2015
- QAR Data Health Monitoring Method of Civil Aircraft Bleed Air SystemJournal of Mechanical Engineering, 2015
- LCAD: A Correlation Based Abnormal Pattern Detection Approach for Large Amount of Monitor Data2014
- A comparison of outlier detection algorithms for ITS dataExpert Systems with Applications, 2010
- Projected outlier detection in high-dimensional mixed-attributes data setExpert Systems with Applications, 2009
- Identification of Outliers1980