Computationally efficient real‐time interpolation algorithm for non‐uniform sampled biosignals
Open Access
- 11 May 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in Healthcare Technology Letters
- Vol. 3 (2) , 105-110
Abstract
This Letter presents a novel, computationally efficient interpolation method that has been optimised for use in electrocardiogram baseline drift removal. In the authors’ previous Letter three isoelectric baseline points per heartbeat are detected, and here utilised as interpolation points. As an extension from linear interpolation, their algorithm segments the interpolation interval and utilises different piecewise linear equations. Thus, the algorithm produces a linear curvature that is computationally efficient while interpolating non‐uniform samples. The proposed algorithm is tested using sinusoids with different fundamental frequencies from 0.05 to 0.7 Hz and also validated with real baseline wander data acquired from the Massachusetts Institute of Technology University and Boston's Beth Israel Hospital (MIT‐BIH) Noise Stress Database. The synthetic data results show an root mean square (RMS) error of 0.9 μV (mean), 0.63 μV (median) and 0.6 μV (standard deviation) per heartbeat on a 1 mV p–p 0.1 Hz sinusoid. On real data, they obtain an RMS error of 10.9 μV (mean), 8.5 μV (median) and 9.0 μV (standard deviation) per heartbeat. Cubic spline interpolation and linear interpolation on the other hand shows 10.7 μV, 11.6 μV (mean), 7.8 μV, 8.9 μV (median) and 9.8 μV, 9.3 μV (standard deviation) per heartbeat.Keywords
This publication has 9 references indexed in Scilit:
- Realtime ECG baseline removal: An isoelectric point estimation approach2014
- Development of Heart and Respiratory Rate Percentile Curves for Hospitalized ChildrenPediatrics, 2013
- A chronology of interpolation: from ancient astronomy to modern signal and image processingProceedings of the IEEE, 2002
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- A filter to suppress ECG baseline wander and preserve ST-segment accuracy in a real-time environmentJournal of Electrocardiology, 1991
- A comparison of the noise sensitivity of nine QRS detection algorithmsIEEE Transactions on Biomedical Engineering, 1990
- Cubic convolution interpolation for digital image processingIEEE Transactions on Acoustics, Speech, and Signal Processing, 1981
- Cubic splines for image interpolation and digital filteringIEEE Transactions on Acoustics, Speech, and Signal Processing, 1978
- VII. Problems concerning interpolationsPhilosophical Transactions of the Royal Society of London, 1779