Signal Persistence of Bispectral Index and State Entropy during Surgical Procedure under Sedation
Open Access
- 1 January 2012
- journal article
- Published by Wiley in The Scientific World Journal
- Vol. 2012, 1-5
Abstract
Introduction. Bispectral index (BIS) and state entropy (SE) are prone to artifacts, especially due to electrocautery (EC). We compared the incidence of artifacts in BIS and SE during surgery under local anesthesia and sedation. Methods. 28 females undergoing breast surgery under local anesthesia and sedation were studied. Simultaneous BIS and SE measurements were recorded every 10 seconds. Artifact was defined as a failure of the device to display a numerical value while the electrodes remained appropriately attached to the patients forehead. Ratio of artifact to good signal was compared between BIS and SE in the presence or absence of EC use. Results. 7679 data points were collected from 28 patients. Overall, artifact incidence was similar in BIS and SE (6.2% and 6.3%, resp.). In the presence of EC (1370 data points), BIS had significantly more artifact compared to SE (18.6% versus 6.4%,Keywords
This publication has 12 references indexed in Scilit:
- Comparison of Spectral Entropy and Bispectral Index Electroencephalography in Coronary Artery Bypass Graft SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2010
- Practical Use of the Raw Electroencephalogram Waveform During General Anesthesia: The Art and ScienceAnesthesia & Analgesia, 2009
- Entropy is more resistant to artifacts than bispectral index in brain-dead organ donorsIntensive Care Medicine, 2006
- A Comparison of State and Response Entropy Versus Bispectral Index Values During the Perioperative PeriodAnesthesia & Analgesia, 2006
- Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic StateAnesthesia & Analgesia, 2005
- Cerebral Monitoring in the Operating Room and the Intensive Care Unit – An Introductory for the Clinician and a Guide for the Novice Wanting to Open a Window to the BrainJournal of Clinical Monitoring and Computing, 2005
- Description of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy ModuleActa Anaesthesiologica Scandinavica, 2004
- Interference of Electromagnetic Operating Systems in Otorhinolaryngology Surgery with Bispectral Index MonitoringAnesthesia & Analgesia, 2003
- Falsely Increased Bispectral Index Values in a Series of Patients Undergoing Cardiac Surgery Using Forced-Air-Warming Therapy of the HeadAnesthesia & Analgesia, 2002
- Falsely Increased Bispectral Index Values in a Series of Patients Undergoing Cardiac Surgery Using Forced-Air-Warming Therapy of the HeadAnesthesia & Analgesia, 2002