Abstract
This study evaluated a reproducible household-scale treatment train for Sasirangan wastewater by assessing alum coagulation–flocculation, lime neutralisation, sedimentation, and filtration, using pH, colour, and settledsludge volume as operational indicators for decentralised monitoring and preliminary unit design. The treatment sequence comprised alum coagulation– flocculation, lime-based pH neutralisation, Imhoff-glass sedimentation, and gravity filtration as a polishing step. Jar tests used 1,000 mL wastewater aliquots with ten replicates (n = 10). A 4% (w/v) alum stock solution was applied at 4,000 mg/L, and lime at 3,200 mg/L, both based on the initial wastewater volume. Because chemical oxygen demand, biochemical oxygen demand, total suspended solids, and dye-specific concentrations were not determined, pH and colour were treated as practical indicators rather than complete measures of regulatory compliance or pollutant removal. Data were analysed using the Statistical Package for the Social Sciences (SPSS), including Shapiro–Wilk normality testing, a one-sample t-test against a 179.2 Pt–Co comparative benchmark, and a paired t-test for pre- and post-filtration colour. Coagulation–flocculation produced stable post-coagulation colour values (mean = 179.95 Pt–Co, SD = 1.48), with no significant difference from the benchmark (t(9) = 1.598, p = 0.144). Lime neutralisation increased pH from acidic post-alum conditions (mean = 4.29, SD = 0.07) to the regulatory range of 6–9 (mean = 6.54, SD = 0.09). Sedimentation supported 30 minutes as a practical retention time, whereas filtration produced no significant additional colour reduction (t(9) = 0.827, p = 0.430).